Configuration with QuickSET
76
QuickSET Configuration Guide
Wide Area DI - Configuration Window
The Wide Area (DI) configuration window is shown in
Figure 82
, below.
Figure 82 Wide Area DI Configuration Window
The line configuration information given below and on the following pages must be supplied by
your service provider. Factory default settings are in bold. The WPIM-DI has two connectors
allowing two devices to share the available Time Slots in a T1 WAN link; an NI (Network
Interface) Port, and a DI (Drop and Insert) Port.
DI Functionality
Enable —
The NI Port is connected to the T1 WAN connection. Any timeslot set to zero will
pass (that timeslot) from the NI Port to the DI Port (see
Figure 83
on the following page). The
clock must either be local or come into the WPIM-DI through the NI Port.
Data From DI —
The DI Port is connected to the T1 WAN connection. Any timeslot set to zero
will pass (that timeslot) from the DI Port to the NI Port. The clock must come into the WPIM-DI
through the NI Port.
Disable —
The Drop and Insert functionality is turned off. The NI Port is connected to the T1
WAN interface and no timeslots are passed to the DI Port regardless of whether they are set to zero
or not.