Preparing and Installing the 9A426-01 Module

 

Unpacking an APIM

 

1. Remove the APIM from the shipping box. (Save the box and packing 

materials in the event the APIM must be reshipped.)

2. Remove the APIM from the non-conductive bag. 

3. Examine the APIM and check for damage. If damage exists, DO NOT proceed; 

contact Cabletron Systems Technical Support. Otherwise, place the APIM 
back into the non-conductive bag, set the APIM aside, and proceed.

 

Figure 2-3. An APIM-21

80 position (female) connector

Содержание 9A426-01

Страница 1: ...903number SmartSwitch 9000 9A426 01 ATM Module User s Guide ...

Страница 2: ......

Страница 3: ...IAL OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Copyright February 1998 by Cabletron Systems Inc 35 Industrial Way Rochester NH 03867 5005 All Rights Reserved Printed in the United Stat...

Страница 4: ...use harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment...

Страница 5: ...in the Radio Interference Regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada ...

Страница 6: ...ipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above directives Manufacturer Legal Representative in Europe Mr Ronald Fotino Mr J Solari ____________________________________________________ ______________________________________________________ Full Name Full...

Страница 7: ...ble Components on the Module s Daughterboard 2 9 DIP Switch 2 10 Removing the daughterboard from the motherboard 2 12 Installing the Module into the SmartSwitch 9000 Chassis 2 16 The Reset Switch 2 18 Chapter 3 Operation LAN Emulation 3 3 System Management Buses 3 3 SMB 1 Bus 3 3 SMB 10 Bus 3 4 System Diagnostic Controller 3 4 DC DC Converter 3 4 INB Network Interface Block 3 5 FDDI Network Interf...

Страница 8: ...pter 5 Specifications Technical Specifications 5 1 CPU 5 1 Memory 5 1 Address Table Size 5 1 Power 5 1 Network Interfaces 5 1 Standards 5 2 Safety 5 2 Service 5 2 Physical 5 3 Dimensions 5 3 Weight 5 3 Environment 5 3 ...

Страница 9: ...pecific Integrated Circuits ASICs collectively known as the SmartSwitch Core The SmartSwitch Core can process data in two modes Traditional Switch When operating as a traditional switch the Fast Packet Switch makes filtering forwarding decisions based on Destination Address with standard IEEE 802 1d learning Secure Fast Switch SFS When operating in SFS mode all filtering forwarding decisions are b...

Страница 10: ... 01 Module has one full implementation of SMT Version 7 3 and SNMP for local and remote management Local management is provided through the RS 232 COM ports on the SmartSwitch 9000 Environmental Module using a standard VT 220 terminal or emulator or via telnet Remote management is achieved through Cabletron s SPECTRUM or any SNMP compliant management tool Switching statistics of the selected FNB i...

Страница 11: ...ndancy on the 9A426 01 Module is evident when an actual switch failover to the redundant link occurs At that time the module will audit the primary link at a user selectable time of day to determine if that link is once again able to function If the primary link is able to function the module will switch back to the primary link The time of day option provides users with the ability to check the p...

Страница 12: ...an one minute Management Information Base MIB Support The 9A426 01 Module provides MIB support including IETF AToM MIB IETF FDDI MIB IETF Bridge MIB and a host of Cabletron Enterprise MIBs LANVIEW LEDs The 9A426 01 Module uses LANVIEW Cabletron Systems built in visual diagnostic and status monitoring system With LANVIEW LEDs you can quickly identify the device port and physical layer status at a g...

Страница 13: ...1 5 Introduction Figure 1 1 The 9A426 01 Module SMB CPU A T M 1 A T M 2 FNB INB 9A426 01 ATM ...

Страница 14: ...Getting Help If you need additional support related to this device or if you have any questions comments or suggestions concerning this manual contact the Cabletron Systems Global Call Center Phone 603 332 9400 Internet mail support ctron com FTP ctron com 134 141 197 25 Login anonymous Password your email address BBS 603 335 3358 Modem setting 8N1 8 data bits No parity 1 stop bit For additional i...

Страница 15: ...to resolve the problem e g changing mode switches rebooting the unit etc The serial and revision numbers of all involved Cabletron Systems products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the device before is this a recurring problem etc Any previous Return Ma...

Страница 16: ...Introduction 1 8 ...

Страница 17: ...the event the module must be reshipped 2 Remove the module from the plastic bag Observe all precautions to prevent damage from Electrostatic Discharge ESD 3 Carefully examine the module checking for damage If any damage exists DO NOT install the module Contact Cabletron Systems Technical Support immediately Never expose the module s components to Electrostatic Discharge Make sure you have attached...

Страница 18: ... s base level circuit board is known as the motherboard The module s second level circuit board is known as the daughterboard The removable daughterboard attaches to the motherboard s connectors and standoffs Both the motherboard and the daughterboard contain components that are accessible to the user Figure 2 1 The 9A426 01 Module s two major circuit boards motherboard daughterboard ...

Страница 19: ...face Module APIM See Figure 2 2 Figure 2 2 User Accessible Components on the 9A426 01 Module s motherboard The User Accessible Components on the motherboard of a 9A426 01 Module are positioned in close proximity to one another Therefore to attain easier access for removing a desired component you may opt to remove an additional component For example you may remove an SRAM SIMM to gain better acces...

Страница 20: ...ns are included in the upgrade kit APIMs The preparation of the 9A426 01 Module includes the installation of at least one ATM Port Interface Module APIM in the module s front panel port a second APIM can be installed for redundancy The module is shipped with no installed APIMs You customize the module to your particular need by selecting from a variety of APIMs and then installing the selected API...

Страница 21: ... in the event the APIM must be reshipped 2 Remove the APIM from the non conductive bag 3 Examine the APIM and check for damage If damage exists DO NOT proceed contact Cabletron Systems Technical Support Otherwise place the APIM back into the non conductive bag set the APIM aside and proceed Figure 2 3 An APIM 21 80 position female connector ...

Страница 22: ...onnectors is to the right See Figure 2 4 2 Locate the module s ATM Port Retaining Plate The plate is secured by two screws and is located on the right side panel of the module s faceplate See Figure 2 4 Figure 2 4 The 9A426 01 Module APIM installation area in insert To install an APIM properly in the 9A426 01 Module you MUST remove the module s ATM Port Retaining Plate Failure to do so can damage ...

Страница 23: ...n Figure 2 4 This area contains four standoffs short metal posts arranged in an irregular rectangle see insert in Figure 2 4 There is a round head screw at each end of these four standoffs 3 Use a phillips head screwdriver to remove the four round head screws from the four standoffs Set the screws aside 4 Remove the APIM from its non conductive bag 5 Locate the APIM s 80 position female connector ...

Страница 24: ... Module s ATM Port Retaining Plate see next page Attaching the 9A426 01 Module s ATM Port Retaining Plate 1 Place the module component side up on a non conductive flat surface Position the module so that the module s front faceplate is facing you 2 Locate the area where the ATM Port Retaining Plate attaches to the faceplate 3 Place the ATM Port Retaining Plate on the module align the retaining pla...

Страница 25: ... on the Module s Daughterboard The user accessible components on the module s daughterboard are located on the underside of the daughterboard These components include an eight position DIP switch a replaceable SMB 1 PROM a replaceable BOOT PROM and sockets for DRAM and FLASH memory You can access the DIP switch without removing the daughterboard However to access the other user accessible componen...

Страница 26: ...ight position DIP switch is located on the module s daughterboard as shown in Figure 2 8 The functions of the switches are listed in Table 2 1 Figure 2 8 Location of DIP Switch on the 9A426 01 Module s Daughterboard 8 6 4 2 7 5 3 1 N O DIP Switch side view in insert ...

Страница 27: ...in NVRAM when the module is powered down and remain there until the switch is toggled again 6 Force BootP Download Toggling this switch after pulling the board out of the SmartSwitch 9000 clears download information from NVRAM and forces image files to be downloaded from the station connected to the EPIM on the Environmental Module configured to act as that module s BOOTP server 5 Reserved For Fac...

Страница 28: ...ight The daughterboard abuts the backplane connectors see Figure 2 1 2 Locate the daughterboard s nine securing screws see Figure 2 9 3 Use a phillips head screwdriver to remove the securing screws Set the screws aside 4 Grasp the daughterboard and lift up 5 Turn the daughterboard over to reveal its user accessible components see Figure 2 10 Never expose the module s components to Electrostatic Di...

Страница 29: ...2 13 Preparing and Installing the 9A426 01 Module Figure 2 9 Daughterboard attached to the 9A426 01 Module securing screws ...

Страница 30: ...Preparing and Installing the 9A426 01 Module 2 14 Figure 2 10 User Accessible components on underside of 9A426 01 Module s Daughterboard DIP Switch BOOT PROM SMB 1 PROM DRAM SIMM slot FLASH SIMM slot ...

Страница 31: ... BOOT PROM install the BOOT PROM Upgrade Kit Installation instructions are included in the upgrade kit FLASH SIMM The 9A426 01 Module is shipped with a 4Mb FLASH SIMM The FLASH SIMM s socket is located on the underside of the module s daughterboard as shown in Figure 2 10 To upgrade the FLASH SIMM refer to the installation instructions included in the FLASH SIMM Upgrade Kit DRAM SIMM The 9A426 01 ...

Страница 32: ... Strap Grounding receptacle in the lower right corner of the SmartSwitch 9000 chassis shown in Figure 2 11 3 Grasp the module and slide it into the slot Make sure that the module s circuit card is between the card guides as shown in Figure 2 11 Check both the upper and lower tracks of the card Take care that the module slides in straight and engages the backplane connectors properly 4 Lock down th...

Страница 33: ...e 2 11 Installing the 9A426 01 Module Circuit Card Card Guides Metal Panel Jack for ESD wrist strap Warning Ensure that the circuit card is between the card guides Lock down the top and bottom plastic tabs at the same time applying even pressure Plastic Tab ...

Страница 34: ...tdown power down the module and or restart the module To reset the module s i960 processor press the reset switch twice within three seconds To shutdown the module press and hold the reset switch for three or more seconds To restart the module press the reset switch momentarily To enhance module security use SNMP management to disable the reset switch Figure 2 12 The Reset Switch Reset Switch SMB ...

Страница 35: ... FNB interfaces FNB 1 or FNB 2 Keep in mind that connecting the module s SmartSwitch ASIC core to an FNB interface also connects the selected FNB to the module s three fixed interface connections the two front panel ATM ports and the INB interface As shown in Figure 3 1 packets can be received simultaneously at the ATM interface the INB interface and if configured by the user one of the FNB interf...

Страница 36: ...n FNB 1 Interface FNB 2 Interface INB Interface FNB 1 Interface FNB 2 Interface INB Interface INB Interface FNB 1 Interface FNB 2 Interface SmartSwitch Core ASICs ATM Interface A T M 1 A T M 2 ATM Interface A T M 1 A T M 2 SmartSwitch Core ASICs ATM Interface A T M 1 A T M 2 SmartSwitch Core ASICs Front Panel Backplane ...

Страница 37: ...ntly installed on your desktop while providing the capability of a high speed uplink to an ATM network As such it enhances your current equipment as well as the equipment s operating system software LANE provides high speed ATM performance without a wholesale swap of hardware System Management Buses There are two management channels within the SmartSwitch 9000 system the SMB 1 and the SMB 10 These...

Страница 38: ... and its supporting logic The diagnostic controller is designed to control the power up sequencing of modules monitor the 9A426 01 Module input and output power parameters keep watch over the main host processor as well as monitor the temperature and control the SMB LANVIEW diagnostic LED Although the diagnostic controller and the main host processor can operate independent of each other if needed...

Страница 39: ...nsmitted onto the selected FNB Conversely FDDI packets received by the module from an FNB are converted by the FNIB into canonical frames and forwarded to the SmartSwitch ASIC core for processing ATM Network Interface Block The 9A426 01 Module s ATM Interface includes an ATM Network Interface Block ANIB ATM cells that enter the module s front panel port are converted by the module s ANIB into cano...

Страница 40: ...ching allows customers to receive many of the benefits of ATM such as security and accountability within LAN infrastructures An equally important SecureFast Virtual Networking feature is a broadcast interception service that resolves issues such as security broadcasts multi casts and network flooding Broadcast interception allows customers to cost effectively control broadcast traffic in a switche...

Страница 41: ...he module and aid in troubleshooting the module The LANVIEW LEDs of the 9A426 01 Module are shown in Figure 4 1 Figure 4 1 The LANVIEW LEDs of the 9A426 01 Module SMB CPU A T M 1 FNB INB 9A426 01 ATM INB Receive INB Transmit FNB Receive FNB Transmit SMB CPU ATM Receive ATM Transmit ...

Страница 42: ...hile booting Yellow Testing Performing power up testing Yellow Flashing Crippled Not fully operational i e one bad port Red Reset Normal power up reset Red Flashing Failed Fatal error has occurred Off No Power No power is being supplied to the module Table 4 2 INB Receive LED LED Color State Green Link exists no activity port is enabled Yellow Flashing Link exists activity port is enabled Red No l...

Страница 43: ... Flashing Fault or error exists Off No activity port is enabled Table 4 4 FNB Receive LED LED Color State Green Link exists no activity port is enabled Yellow Flashing Link exists activity port is enabled Red No link port is disabled Red Flashing Link exists port is disabled Off No link no activity port is enabled Table 4 5 FNB Transmit LED LED Color State Green Flashing Activity port is enabled Y...

Страница 44: ...VIEW LED s Figure 4 2 show the location of LANVIEW LEDs on an APIM For further information about a particular APIM refer to that specific APIM s documentation Figure 4 2 The LANVIEW LEDs of an APIM 22 Table 4 6 ATM Receive LEDs LED Color State Yellow Flashing Activity Red Failure Off No Activity Table 4 7 ATM Transmit LEDs LED Color State Green Flashing Activity Red Failure Off No Activity 1 2 3 4...

Страница 45: ...us STS LED Table 4 9 indicates the state of the APIM Link LNK LED Table 4 8 APIM Status STS LED LED Color State Green Active Amber Reset Red Failure Table 4 9 APIM Link LNK LED LED Color State Green Link is established Amber Off no link Red Off no link ...

Страница 46: ...LANVIEW LEDs 4 6 ...

Страница 47: ...ry 16 Mb standard expandable Flash Memory 4 Mb standard expandable Address Table Size 16 000 entries expandable Power 100 125 VAC or 200 250 VAC 50 60 Hz Network Interfaces Access to the ATM network is made via up to two front panel ATM Port Interface Modules APIMs supporting standard ATM speeds and media types ...

Страница 48: ...I Requirements of FCC Part 15 Class A EN 55022 Class A VCCI Class I The EMC requirements of EN 50082 1 IEC 801 2 ESD IEC 801 3 Radiated susceptibility IEC 801 4 EFT Service MTBF MHBK 217E 200 000 hrs MTTR 0 5 hr It is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions CAUT...

Страница 49: ...4 0 H x 6 0 W centimeters 13 8 D x 17 4 H x 1 2 W inches Weight Unit 4 525 kgs 10 lbs Shipping 6 787 kgs 15 lbs Environment Operating Temperature 5 to 40 C 41 to 104 F Storage Temperature 30 to 90 C 22 to 164 F Relative Humidity 5 to 95 non condensing ...

Страница 50: ...Specifications 5 4 ...

Отзывы: