[6] Downline Upgrade
4-18 Configuring the Module in a DIGITAL MultiSwitch 900
Initializing the Process
To initiate the DLU process, complete the following steps:
When you press <Return>, you initiate the DLU process over the LAN that is
connected to the load host. The screen displays the following message:
Step
Action
Example
1
Press Return.
<Return>
2
If the file is in the default TFTP directory,
enter the firmware image file name and
press Return. (The TFTP load host
conventions specify the format of the
firmware image file name).
If the file is not in the default TFTP
directory, enter the complete path name and
press Return.
DLMT2100.BIN
<Return>
/BOOT/
DLMT2100.BIN
<Return>
3
Enter the IP address of the TFTP load host,
and press Return. The screen displays the
following message:
16.20.40.156
4
Press Return.
<Return>
in-band network interface. The
device becomes nonfunctional for
that the flash load is in
progress.
Press Return Key to Start Load
Ctrl/C to abort] . . .
up to 10 minutes during the time
Load will be initiated over the
DLU Process Started!
..................................