Page 5-14
NAVIGAT X MK 1 Mod. 10 / SR-180 MK 1 Mod. 10
056310
3-149 MK110ENG.P65
Function test
1)
Energize the gyrocompass system.
2)
In the service setup 2, select the gyrosphere data sub-menu.
Observe the gyrosphere current:
Directly after power-up, the gyrosphere current should not exceed 550 mA.
The current will gradually fall while the gyrosphere settles.
Within 45 minutes after power-up, the gyrosphere current must have dropped
below 300 mA.
GYROSPHERE DATA
GYRO CURR
234 mA
...
.
.
...
.
.
.....
.
.
.
....
.
TEMPERATURE
40 °C
PH.BRIDGE
10 mV
After initial power-up, gyrosphere
current must drop below 300 mA
within 45 minutes.
If, after 45 minutes of operation, a gyrosphere current above 300 mA is dis-
played in the gyrosphere data sub-menu, measure the AC-voltage present
across resistor R150 (1
Ω
) on the masterboard. The voltage across R150 in
mV equals the gyrosphere current in mA.
Caution:
If 45 minutes after power up, the gyrosphere current has not dropped below
300 mA, the gyrosphere is defective and must be replaced.
Содержание NAVIGAT X MK 1 Mod. 10
Страница 30: ...Page 3 08 NAVIGAT X MK 1 Mod 10 SR 180 MK 1 Mod 10 056310 3 149 MK110ENG P65 this page intentionally left blank...
Страница 44: ...Page 4 14 NAVIGAT X MK 1 Mod 10 SR 180 MK 1 Mod 10 056310 3 149 MK110ENG P65 this page intentionally left blank...
Страница 66: ...Page 5 22 NAVIGAT X MK 1 Mod 10 SR 180 MK 1 Mod 10 056310 3 149 MK110ENG P65 this page intentionally left blank...
Страница 74: ...Page A 08 NAVIGAT X MK 1 Mod 10 SR 180 MK 1 Mod 10 056310 3 149 MK110ENG P65 this page intentionally left blank...
Страница 75: ......
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 79: ......
Страница 80: ......
Страница 81: ......
Страница 82: ......