Page 4-06
NAVIGAT X MK 1 Mod. 10 / SR-180 MK 1 Mod. 10
056310
3-149 MK110ENG.P65
4.5.2
Storing the Calibration Table
1)
In the user setup, select the magnetic compass calibration sub-menu.
USER SETUP
MAG.C.CAL. TABLE
ON
F1 TO ENTER VALUES
.....
.
..
.
.........
.
.
.
.
0°
0,8°
-0,8°
10°
0,9°
-0,9°
20°
1,0°
-1,0°
correction
value
magnetic
compass
heading
hdg. display
NAVIGAT X Mk 1
(uncalibrated)
USER SETUP
MAG.C.CAL.TABLE 00
HEADING 000.0°
CORR. VALUE
-00.8°
.....
.
.
.
.....
.
.
..
4 1
enter heading/correction
value pairs
2)
4 1
Press keys to go to the calibration table entry screen.
3)
Enter heading/correction value pairs:
2
/
3
increase / decrease value at cursor position
6
/
5
move cursor forward / back
4 6
confirm set value; when both heading and correction values have
been confirmed, the entry is stored in the calibration table
4 2
go to next table entry
4 3
go to previous table entry
4 5
+
4 6
clear entry from calibration table
Note:
The calibration table is stored in the system's permanent memory. If the
complete set of table entries is to be altered (e.g. when a new magnetic
heading sensor has been fitted), clear the old entries from the table first.
Содержание NAVIGAT X MK 1 Mod. 10
Страница 30: ...Page 3 08 NAVIGAT X MK 1 Mod 10 SR 180 MK 1 Mod 10 056310 3 149 MK110ENG P65 this page intentionally left blank...
Страница 44: ...Page 4 14 NAVIGAT X MK 1 Mod 10 SR 180 MK 1 Mod 10 056310 3 149 MK110ENG P65 this page intentionally left blank...
Страница 66: ...Page 5 22 NAVIGAT X MK 1 Mod 10 SR 180 MK 1 Mod 10 056310 3 149 MK110ENG P65 this page intentionally left blank...
Страница 74: ...Page A 08 NAVIGAT X MK 1 Mod 10 SR 180 MK 1 Mod 10 056310 3 149 MK110ENG P65 this page intentionally left blank...
Страница 75: ......
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 79: ......
Страница 80: ......
Страница 81: ......
Страница 82: ......