System Administration with EmWeb
UM1600-2-A 2002
47
Note:
(1) If you configure “Transmit Rate Adaptation” as “Fixed”, it is
recommended to configure the value of “minimum transmit rate” and
“maximum transmit rate” on CO side or RT side the same. However,
the value of CO side and RT side may not be the same.
(2) Line profile can be created maximum up to 10 profiles.
Creating a Alarm Profile
{Create Alarm Profile}
This section describes how to create an ADSL alarm profile.
1. Click on “
Create Alarm Profile
” of DSL Profile configuration Menu.
The
Create Alarm Profile
screen appears as follows:
2. Configure the name of alarm profile as
alarm1
.
3. Configure the alarm profile on CO side (Down Stream). For example,
Configure the Lofs, Loss, Lols, Lprs, Ess, and initial failure trap as
30sec, 10sec,
50sec
,
5sec
,
4sec
, and
Enable
initial failure trap.
4. Configure the alarm profile on RT side (Up Stream). For example,
Configure the Lofs, Loss, Lprs, and Ess as
30sec, 2sec, 2sec
,
and
5sec
.
5. Click on the
Apply
button to submit your changes, or click on the
Cancel
button if you want to clear all the values you have configured.
Note:
The alarm profile can be created maximum up to 10 profiles.