3.6.4. For the 981/755 Home and Away Sensors:
981/755 Home/Away Location
a.
Loosen the nut and screw the AZ/AW sensor all the way until it hits the bearing, and
then roll it back half a turn. Use 0.8mm feeler gauge and tighten the bolt.
b.
Connect the sensor to the internal harness and place the antenna down. Move the
antenna to the home position and if the Home Sensor is properly aligned with the target
the LED should be ON.
c.
From the iNetVu Software Controls screen the Azimuth ST should be active. Attempt to
auto-stow the platform.
d.
To test the Away Sensor, move the platform to roughly 180 or -180 degrees. If the
Away Sensor is properly aligned with the target the LED should be ON.
6.