8 | Parameter Description
34 / 56
0870166596_MV0040-0080C-D_PCI_A0004_IM_de_MD
Max. Freq.
Min. Freq.
Frequency Reference
Analogue input AI [%]
-100
0
50
100
200
Description of upper figure:
Blue line shows an example with Custom Min. = 0% and Custom Max = 200%. These
settings provide a frequency range between Min. Frequency and (Max. Frequency –
Min. Frequency)/2. With minimum analogue signal the frequency reference is at min-
imum value of the set frequency range (Min. Frequency), and with maximum analogue
signal the frequency reference is at (Max. Frequency - Min. Frequency)/2.
Green line shows an example with Custom Min. =100% and Custom Max = 200%.
These settings provide a frequency range always at Min. Frequency. The frequency
reference is at Min. Frequency within the entire analogue signal range.
Orange line shows an example with Custom Min. = 0% and Custom Max = 50%.
These settings provide a frequency range between Min.- and Max. Frequency. The
frequency reference changes linearly within the frequency range with the analogue
signal between the 0% and 50% of its range. With the analogue signal between 50%
and 100% of its range, the frequency reference is always at its maximum value (Max.
Frequency).