Parameter Description | 8
0870166596_MV0040-0080C-D_PCI_A0004_IM_de_MD
29 / 56
When value is greater than zero, acceleration and deceleration ramps have a S
shape. The parameter is the time needed to reach full acc/dec. The start and end of
acceleration and deceleration ramps can be smoothed with this parameter. Setting
value 0 gives a linear ramp shape which causes acceleration and deceleration to act
immediately to the changes in the reference signal.
Setting value 0.1…10 seconds for this parameter produces an S-shaped acceleration/
deceleration. The acceleration time is determined with parameters P1.3 and P1.4.
P1.3, P1.4
[Hz]
[t]
P2.13
P2.13
These parameters are used to reduce mechanical erosion and current spikes when
the reference is changed.
P2.14 Control Place 2
Alternative Run and direction control. Activated by digital input, defined in P4.14.
0: I/O terminals
1: Keypad
2: Fieldbus
P2.15 Frequency Reference Source 2
Alternative source of frequency reference. Activated by digital input, defined in P4.15
or fieldbus.
0: Analogue input AI1
1: Analogue input AI2
2: PID control
3: Motor potentiometer
4: Keypad
5: Fieldbus
P2.16 Motor Potentiometer Ramp
Speed variation ramp.
P2.17 Motor Potentiometer Memory
0: No reset
1: Reset at stop and power down
Содержание Mink MV 0040 C
Страница 55: ...Note ...