7 | Parameter Overview
20 / 56
0870166596_MV0040-0080C-D_PCI_A0004_IM_de_MD
7.8 Analogue Outputs: Menu PAR G6
Code Parameter
Min.
Max.
Unit Default ID
Description
P6.1
Analogue output function 0
8
2
307
0 = Not used (fixed 100%)
1 = Frequency reference (0 – f
max
)
2 = Output frequency (0 – f
max
)
3 = Motor speed (0 – max. speed)
4 = Output current (0 – I
nMotor
)
5 = Motor torque (0 – T
mnMotor
)
6 = Motor power (0 – P
nMotor
)
7 = PID output (0 – 100%)
8 = Fieldbus (0 – 10000)
P6.2
Analogue output
minimum
0
1
0
310
0 = 0 V
1 = 2 V
P6.3
Analogue output scale
0
1000
%
100
311
Scaling factor
P6.4
Analogue output filter
time
0
10
s
0.10
308
Filtering time of analogue output signal
0 = Not filtering
Visibility of the group depends on P1.16
7.9 Group Supervisions: Menu PAR G7
Code Parameter
Min.
Max.
Unit Default ID
Description
P7.1
Frequency supervision 1 0
12
0
315
0 = Not used
1 = Low limit
2 = High limit
P7.2
Frequency supervision
value
0
P1.2
Hz
0
316
Output frequency supervision threshold
P7.3
Current supervision
0
2xI
H
A
0
1811 Current supervision threshold
P7.4
Analogue input
supervision signal
0
2
0
356
0 = AI1
1 = AI2
P7.5
Analogue input
supervision ON level
0
100
%
80
357
ON threshold AI supervision
P7.6
Analogue input
supervision OFF level
0
100
%
40
358
OFF threshold AI supervision
P7.7
External brake open
frequency
0
10
Hz
2
1808 Frequency threshold for brake open
P7.8
External brake open
current
0
100
%
30
1810 Current threshold for brake open
P7.9
External brake close
frequency
0
100
Hz
2
1809 Frequency threshold for brake close
(Start = 0)
P7.10 Process source select
0
5
2
1036 Selection of variable proportional
to process:
0 = PID feedback value
1 = Output frequency
2 = Motor speed
3 = Motor torque
4 = Motor power
5 = Motor current
P7.11 Process value decimal
digits
0
3
1
1035 Decimals on display
Содержание Mink MV 0040 C