177
I-Modell - 11/12 - Ausgabe 09/11 - 2096165 - BUE-0056-05EN
Appliances
9
Gas operation
If the automatic mode is selected, 230 V power supply is
not
connected and
the vehicle's engine is
not running
, the AES selects the gas supply. When
selecting gas operation the ignition fuse is opened automatically so gas can
get into the burner. At the same time the electronic ignition is activated. If the
gas flame is extinguished, e.g. by blast of wind, the ignition is activated imme-
diately and re-ignites the gas. In the case of a fault in gas operation the text
"GAS" flashes in the operating indicator (Fig. 190,4).
Change-over between
energy sources
When changing over from 230 V or 12 V to gas, delay times are built into the
AES. For example, when changing over from 12 V operation to gas operation,
a 15 minute delay is built in the AES. This prevents a change-over to gas oper-
ation when the vehicle is stopped briefly and the engine is switched off (e.g.
stop to fill tank).
Refrigerating temperature
control
When turned on the first time the refrigerator automatically selects the middle
thermostat position. This position can be adjusted manually by using the
switch for temperature setting (Fig. 190,6). The indicator LEDs (Fig. 190,5)
show the selected thermostat position. The refrigerating temperature for the
three types of energy is set with the switch. It takes a few hours till the refrig-
erator reaches its normal operating temperature. When changing over the
operating mode the thermostat setting will be maintained. The refrigerating
temperature is retained regardless of the type of power being used.
Manual operation
Switching on:
Open the regulator tap on the gas bottle and the gas isolator tap "Refriger-
ator".
Press the on/off switch/energy selector switch (Fig. 190,1) down for 2 sec-
onds in order to switch on the appliance. The operating mode selected
most recently is shown in the operating indicator (Fig. 190,4).
Select the energy type with the on/off switch/energy selector switch
(Fig. 190,1).
Set the refrigerating temperature on the switch for temperature setting
(Fig. 190,6). The indicator LEDs (Fig. 190,5) show the selected thermostat
position.
When operated with 12 V, the refrigerator draws power only from the living
area battery.
X
Never let gas escape unburned due to danger of explosion.
Z
Open the regulator tap on the gas bottle and the gas isolator tap "Refriger-
ator".
X
Open flames are prohibited at petrol stations. If the stop takes longer
than 15 minutes, the refrigerator has to be turned off at the energy
selector switch.
Содержание I 2012
Страница 2: ...I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Instruction manual...
Страница 8: ...Contents 8 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN...
Страница 48: ...48 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN During the journey 4...
Страница 106: ...106 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Gas system 7...
Страница 143: ...143 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Electrical system 8 Fig 151 Circuit diagram interior EBL 220...
Страница 180: ...180 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Appliances 9...
Страница 214: ...214 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Care 11...
Страница 242: ...242 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Wheels and tyres 13...
Страница 258: ...258 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Special equipment 15...
Страница 266: ...266 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Technical data 16...
Страница 278: ...278 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Helpful notes 17...
Страница 292: ...Index 292 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN...