134
I-Modell - 11/12 - Ausgabe 09/11 - 2096165 - BUE-0056-05EN
Electrical system
8
8.11
230 V power supply
The 230 V power supply provides electricity for:
z
sockets with earth contact for appliances with maximum 16 A
z
refrigerator
z
transformer/rectifier
z
an auxiliary charging unit
z
air conditioning unit
The electrical appliances connected to the 12 V power supply of the living area
are supplied with voltage by the living area battery.
Connect the vehicle to an external 230 V power supply system as often as
possible. The charger module in the transformer/rectifier automatically
charges the living area battery. In addition to this, the starter battery is charged
with a float charge of approx. 2 A.
Depending on the equipment, the air conditioning unit and other optional
devices are fuse-protected by their own safety cut-out (16 A).
8.11.1
230 V connection
Requirements concerning
the 230 V connection
z
The connection cable, the plug connectors at the point of supply and the
plug connector to the vehicle must comply with IEC 60309. The standard
designation for the plug connectors is "CEE blue".
z
Use H07RN-F rubber sheathed cable with a minimum cable cross-section
of 2.5 mm² and a maximum length of 25 m.
z
Earth contact connectors (safety) are not permitted. The interconnection of
CEE/safety adapters is also prohibited.
8.11.2
Connecting 230 V power supply
The vehicle can be connected to an external 230 V power supply.
X
Only allow qualified personnel to work on the electrical system.
X
Have the vehicle's electrical system checked by a qualified electrician at
least once every 3 years. If the vehicle is used frequently, an annual
check is recommended.
X
The external 230 V power supply must be protected by fuse with a fault
current protection switch (FI-switch, 30 mA).
X
To prevent overheating, the cable must be fully uncoiled from the cable
reel.
X
In case of doubt or if the 230 V supply is not available or is faulty, contact
the operator of the power supply device.
Z
The 230 V connection in the vehicle is equipped with a fault current protec-
tion switch (FI-switch).
Z
For the connection points on camp sites (camping distributors) fault current
protection switches (FI-switches, 30 mA) are obligatory.
Содержание I 2012
Страница 2: ...I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Instruction manual...
Страница 8: ...Contents 8 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN...
Страница 48: ...48 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN During the journey 4...
Страница 106: ...106 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Gas system 7...
Страница 143: ...143 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Electrical system 8 Fig 151 Circuit diagram interior EBL 220...
Страница 180: ...180 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Appliances 9...
Страница 214: ...214 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Care 11...
Страница 242: ...242 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Wheels and tyres 13...
Страница 258: ...258 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Special equipment 15...
Страница 266: ...266 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Technical data 16...
Страница 278: ...278 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Helpful notes 17...
Страница 292: ...Index 292 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN...