Model 9180
burster
Digital Panelmeter
Page 4-40
4.4.6
Diagram for configuring the RS485 output
Type 9180
4.4.7
Programming instructions
The above figure shows
Module 50
configured with the serial interface.
The module consists of 5 independent access menus which can be used to configure the
following parameters:
●
Menu 51 -SoFt-
:
Selects the
DITEL
or
ISO 1745
protocol
●
Menu 52 -bAud-
:
Selects baudrate
●
Menu 53 -AdrS-
:
Sets addresses
●
Menu 54 -trAnS-
:
Activates the
SEnd
command
If this command is activated the configuration of this device can be sent
to other devices connected via the RS485 and working with the ISO 1745
protocol.
Detailed instructions for each menu step are found on pages 4-32/33.
●
Menu 55 -dLy-
:
Sets the delay time between command reception and response.
Detailed instruction for each menu step can be found on page 4-45.