4.2.7
Display of the limit value settings in operating mode
To register alarm status the device is equipped with 4 LED displays in the right hand section of the
display. The LEDs are numbered from 1 to 4 (but for the
2RE
option only the first two are used).
The programmed switching point values can be displayed by pressing the "
LIMIT
" key (also with time
delay) during normal operation of the device.
The switching point value is displayed in the secondary display while the letter "
L
" appears in the
auxiliary display, followed by the number of the corresponding switching point.
The switching points are displayed by pressing the "
LIMIT
" button in sequence.
When exceeding the nominal range (OVFLO), all of the outputs and LED displays corresponding to
the switching points are deactivated.
M
A
X
M
I
N
1
HOLD
TARA
2
TARE
RESET
ESC
LIMIT
MAX/MIN
DATA
ENTER
3
4
M
A
X
M
I
N
1
HOLD
TARA
2
TARE
RESET
ESC
LIMIT
MAX/MIN
DATA
ENTER
3
4
4-21
Program the value of the switching point
with aid of the "
" and "
" keys.
Remember that
SET2
is logically
combined with
SET1
and
SET4
with
SET3
.
ENTER:
Confirms your entry and
automatically takes you to the
input level of programming mode
(
-Pro-
).
ESC
:
Returns you to the input level of
programming mode (Display
-Pro-
)
Fig. 4.2.6k
Содержание 9180
Страница 2: ...Model 9180 burster Digital Panelmeter Page ...
Страница 3: ...burster Digital Panelmeter Model 9180 Page ...
Страница 4: ...Model 9180 burster Digital Panelmeter Page ...
Страница 8: ...Model 9180 burster Digital Panelmeter Page ...
Страница 12: ...Model 9180 burster Digital Panelmeter Page ...
Страница 104: ...Model 9180 burster Digital Panelmeter Page ...
Страница 105: ...burster Digital Panelmeter Model 9180 Page 6 1 A P P E N D I X Example BASIC ...
Страница 106: ...Model 9180 burster Digital Panelmeter Page 1 ...
Страница 107: ...burster Digital Panelmeter Model 9180 Page 2 ...
Страница 108: ...Model 9180 burster Digital Panelmeter Page 3 ...
Страница 109: ...burster Digital Panelmeter Model 9180 Page 4 ...