4.

 

   INSTALLATION INSTRUCTIONS 

Before 

working  on  pipe  work,  plug  the  ends  to  prevent  the  entry  of  debris.  Decide  upon  the 

route for the gas and lay pipes as required. Where pipes pass through walls they must be sleeved.  

Before 

connecting  any  pipes  to  the  appliance,  fully  purge  pipes  of  debris  or  swarf  etc.  and 

connect  the  gas  supply  to  the  8mm  elbow  on  the  fire.  Leak  test  the  supply  using  an  approved 
method.    Fires  can  be  connected  to  the  supply  using  semi  rigid  pipe  i.e.  copper  tube  also 
independently  certified,  hand  bendable  corrugated  stainless  steel  connection  pipe  (such  as 
Forma Pipe ™) may be used with this appliance 
Note: An isolating valve must be situated near the appliance for servicing.  

 

Overall inset depths -  

Fully inset 155mm  Semi inset 95mm   In Cavity box 100mm 

 

4.1

 

The appliance is a flueless visual flame appliance designed to be installed into a fireplace 
opening, a rebated fire surround or free standing with its own outer case.

 

It can also be 

installed  partially  inset  in  shallower  fireplaces.  It  must  be  placed  on  a  non  combustible 
surface  of  minimum  12mm  thickness.    The  surface  on  which  the  appliance  is  to  stand 
must be flat, level and square to the back panel. Failure to observe this could result in the 
appliance leaning away from the fireplace.  

4.2

 

For a free standing installation the appliance can be fitted with a deep spacer kit (optional 
extra part no. SPACERKIT) and can stand directly against a wall. Care should be taken with 
wall coverings as it may discolour them over time. 

4.3

 

The  fire  comes  with  a  60mm  spacer  fitted  to  the  front  trim,  we  recommend  that  this 
spacer is left on (mandatory for slide control) as it will keep the surfaces of the fireplace 
cooler.  Any  combustible  materials  directly  behind  the  fire  frame  or  back  panel  must  be 
removed  and  replaced  with  suitable  non  combustible  material  such  as  superlux  board, 
cement or similar.

 

4.4

 

Note:  Burley  manufacture  purpose  made  surrounds,  which  have  been  specially  tested 
with  the  appliance  for  compatibility.    (This  includes  the  wooden  hearth)  If  a  Burley 
Surround  is  used  then  the  fires  must  be  installed  as  supplied  with  the  60mm  spacer 
fitted

 Where any other fireplaces or surround are used, the following guidelines must 

be adhered to:

 

The  fire  surround,  back  panel,  hearth  and  all  paints  /  lacquers  etc  must  be  of  minimum 
150

o

c rating. Please ensure this is the case and if necessary check with the manufacturer, 

as we cannot be held responsible for subsequent damage. If in doubt leave the spacer on. 

4.5

 

Ensure adequate clearance from the fire to allow it to expand in the fireplace opening or 
it  may  crack  the  marble  back  panel.    The  fireplace  opening  sizes  should  be  as  per  fig  1 
above. 

4.6

 

To  prevent  heat  from  entering  the  area  between  the  fireplace  back  panel  and  wall,  the 
void  must  be  blocked  or  packed  with  a  non-flammable  material  and  the  supplied  cavity 
box must be used. 

  

620

 

 

 

Min

 

 

 

Flat

 

 

 

Area

 

 

 

550

 

 

 

Min

 

 

 

575

 

 

 

Max

 

 

 

520 Min Flat Area

 

 

 

400

 

 Min

 

 

 

440 Max

 

 

 

Fig 1 

 

 

 Fireplace opening sizes

 

 

 

Содержание EMPATHY

Страница 1: ...ONS WITH THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4240Inst G20 31 Issue March...

Страница 2: ...ST EVERY SINGLE GAS FIRE IT PRODUCES BURLEY IS IN THE UNIQUE POSITION OF KNOWING THAT EVERY APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER Fireguards A fireguard is not supplied with this appli...

Страница 3: ...l should cease and be replaced with the ticking sound of the spark igniter When the pilot flame is lit the igniter will stop another acoustic signal will confirm the pilot has been established if the...

Страница 4: ...ceiver unit to its original position REPLACE THE HEATSHIELD over the unit Press here and slide down CAUTION With the exception of battery replacement the battery holder must be located within the heat...

Страница 5: ...urn slowly anticlockwise to the ignition position A click will be heard and the pilot under right side of fuel bed should light If it does not repeat the operation a few times to purge any air in the...

Страница 6: ...ift the control lever to the top of its travel 6 The off position on the side of the fire may not correspond exactly with the control lever This is only intended as an indication 1 12 Battery Replacem...

Страница 7: ...the carton for damage before unpacking If it is obviously damaged consult the supplier as to whether to proceed with the installation 2 2 Make sure the carton is stood upright and open the top Remove...

Страница 8: ...cubic feet ft to cubic metre m divide the room volume in cubic feet by 35 3 3 7 The appliance must not be installed in high rise blocks of flats bed sitting rooms basements which are not open on at l...

Страница 9: ...o SPACERKIT and can stand directly against a wall Care should be taken with wall coverings as it may discolour them over time 4 3 The fire comes with a 60mm spacer fitted to the front trim we recommen...

Страница 10: ...from the cavity causing heat build up on the fire surround back panel or moisture ingress from the cavity 4 12 Any under grate draught devices must be sealed off 4 13 If using the fire in a hole in t...

Страница 11: ...tags clip onto the enamelled glass rails 6 4 DO NOT ATTEMPT TO USE THE APPLIANCE WITH BROKEN DAMAGED GLASS OR COALS Contact our service department 01572 756956 6 5 Decide upon the route for the gas su...

Страница 12: ...ay Do not force the valve cable plug when inserting into the receiver it only fits one way HT Lead SW yellow TC red Valve Cable Fit four AA 1 5V batteries into the receiver unit and the PP3 9V battery...

Страница 13: ...on every other gas appliance in the house and re check the pressure The pressure must still be within the tolerance of 1mb Now turn off all the other gas appliances and turn the fire down to pilot on...

Страница 14: ...atures 13 o c 45 o c but for more accurate monitoring of room temperature it is advised that the sensing bulb is removed from the fire and carefully moved to a cooler location up to 1 metre away takin...

Страница 15: ...e burner assembly in the chassis Remove the burner tray and examine it for general condition Discolouration of the burner surface is normal Clean around the air inlet removing all lint in the area of...

Страница 16: ...the manufacturer See the additional information on testing 11 PARTS LIST Part Part No Front Ceramic Coal COA4241F Rear Ceramic Coal COA4241B Oxypilot NG Check if SIT or Seagas Oxypilot LPG Check if SI...

Страница 17: ...as efficient as it was when brand new Burley manages to achieve this by designing the fire to ensure that the catalytic converter is in exactly the right position for long life and maximum efficiency...

Страница 18: ...y gas appliance must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a Gas Safe registered installer formerly CORGI or our own e...

Страница 19: ...t is important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncert...

Страница 20: ...iglo fires are protected by UK patents 2193802 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 725570 Fax 01572 724390 www burley co uk...

Отзывы: