INTRODUCTION 

Thank you for choosing this burley product. All of our products carry a CE mark which is awarded 
by an independent test house (notified body) and shows the fires have been type tested to meet 
the essential requirements of the European Gas Appliance Directive and the appropriate British 
Standards. 

A thermostat in the burner control system adjusts heat output to maintain a room temperature, 
which can easily be set by the user. There is also a separate control to adjust the flame effect as 
required. Please demonstrate its operation to the customer before leaving. 

 

An  oxygen  depletion  sensing  pilot  light  is  also  fitted  and  will  sense  any  significant  oxygen 
depletion in the room and shut the fire down safely.  

 

DUE  TO  THE  SENSITIVE  NATURE  OF  THE  OXY  PILOT,  IT  IS  NOT  UNUSUAL  FOR  THE  PILOT  TO 
EXTINGUISH  UP  TO/AFTER  1  MINUTE  WHEN  FIRST  LIT.  RELIGHT  AND  THE  PILOT  WILL  STAY 
ALIGHT.  THIS  IS  DUE  TO  THE  MOIST  GASES  FORMED  BY  THE  PILOT  DROPPING  DOWN  AND 
SNUFFING  IT  AS  WELL  AS  THE  COLD  METAL  WORK.  IT  IS  SAFE  TO  LEAVE  THE  PILOT  ON  24 
HOURS A DAY TO MAKE LIGHTING EASIER. 

 

BURLEY  APPLIANCES  IS  THE  ONLY  COMPANY  TO  BENCH  RUN  AND  THOROUGHLY  TEST  EVERY 
SINGLE GAS FIRE IT PRODUCES. BURLEY IS IN THE UNIQUE POSITION OF KNOWING THAT EVERY 
APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER.

  

Fireguards 

A  fireguard  is  not  supplied  with  this  appliance;  however  it  is  recommended  that  a 

fireguard to BS6539 or BS6778 is fitted if the fire is to be used in the presence of young children, 
the elderly and the infirm. 

 

Gas appliances must be installed in accordance with the rules in force. In the UK it is the law that 
all  gas  appliances  must  be  installed  by  a  Gas  Safe™  registered  installer  (formerly  CORGI),  in 
accordance with the Gas Safety (Installation and Use) regulations (as amended). The installation 
must also be in accordance with the relevant parts of local and national building regulations and 
in  accordance  with  BS5871  pt4  except  where  Burley  instructions  state  differently.  For  the 
Republic  of  Ireland,  reference  should  be  made  to  IS813  and  ICP3  and  any  guidance  notes  from 
Bord Gais. Failure to have the fire fitted by a qualified person nullifies 

ALL

 guarantees. 

 

Declaration of Conformity 

Burley  Magiglo  Ltd.  declares  that  the  appliance  described  in  “Technical  data”  conforms  to  the 
following standard(s) BS EN 14829: 2007 

Efficiency Declaration 

This appliance has a thermal efficiency of 100% giving an Energy Efficiency Index of 91%. This is 

 

A

 rated on all variants/options & emits less than 130mg/kWh NOx. 

 

 

 

 

 

 

 

 

 

 

Содержание EMPATHY

Страница 1: ...ONS WITH THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4240Inst G20 31 Issue March...

Страница 2: ...ST EVERY SINGLE GAS FIRE IT PRODUCES BURLEY IS IN THE UNIQUE POSITION OF KNOWING THAT EVERY APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER Fireguards A fireguard is not supplied with this appli...

Страница 3: ...l should cease and be replaced with the ticking sound of the spark igniter When the pilot flame is lit the igniter will stop another acoustic signal will confirm the pilot has been established if the...

Страница 4: ...ceiver unit to its original position REPLACE THE HEATSHIELD over the unit Press here and slide down CAUTION With the exception of battery replacement the battery holder must be located within the heat...

Страница 5: ...urn slowly anticlockwise to the ignition position A click will be heard and the pilot under right side of fuel bed should light If it does not repeat the operation a few times to purge any air in the...

Страница 6: ...ift the control lever to the top of its travel 6 The off position on the side of the fire may not correspond exactly with the control lever This is only intended as an indication 1 12 Battery Replacem...

Страница 7: ...the carton for damage before unpacking If it is obviously damaged consult the supplier as to whether to proceed with the installation 2 2 Make sure the carton is stood upright and open the top Remove...

Страница 8: ...cubic feet ft to cubic metre m divide the room volume in cubic feet by 35 3 3 7 The appliance must not be installed in high rise blocks of flats bed sitting rooms basements which are not open on at l...

Страница 9: ...o SPACERKIT and can stand directly against a wall Care should be taken with wall coverings as it may discolour them over time 4 3 The fire comes with a 60mm spacer fitted to the front trim we recommen...

Страница 10: ...from the cavity causing heat build up on the fire surround back panel or moisture ingress from the cavity 4 12 Any under grate draught devices must be sealed off 4 13 If using the fire in a hole in t...

Страница 11: ...tags clip onto the enamelled glass rails 6 4 DO NOT ATTEMPT TO USE THE APPLIANCE WITH BROKEN DAMAGED GLASS OR COALS Contact our service department 01572 756956 6 5 Decide upon the route for the gas su...

Страница 12: ...ay Do not force the valve cable plug when inserting into the receiver it only fits one way HT Lead SW yellow TC red Valve Cable Fit four AA 1 5V batteries into the receiver unit and the PP3 9V battery...

Страница 13: ...on every other gas appliance in the house and re check the pressure The pressure must still be within the tolerance of 1mb Now turn off all the other gas appliances and turn the fire down to pilot on...

Страница 14: ...atures 13 o c 45 o c but for more accurate monitoring of room temperature it is advised that the sensing bulb is removed from the fire and carefully moved to a cooler location up to 1 metre away takin...

Страница 15: ...e burner assembly in the chassis Remove the burner tray and examine it for general condition Discolouration of the burner surface is normal Clean around the air inlet removing all lint in the area of...

Страница 16: ...the manufacturer See the additional information on testing 11 PARTS LIST Part Part No Front Ceramic Coal COA4241F Rear Ceramic Coal COA4241B Oxypilot NG Check if SIT or Seagas Oxypilot LPG Check if SI...

Страница 17: ...as efficient as it was when brand new Burley manages to achieve this by designing the fire to ensure that the catalytic converter is in exactly the right position for long life and maximum efficiency...

Страница 18: ...y gas appliance must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a Gas Safe registered installer formerly CORGI or our own e...

Страница 19: ...t is important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncert...

Страница 20: ...iglo fires are protected by UK patents 2193802 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 725570 Fax 01572 724390 www burley co uk...

Отзывы: