Page 12 of 20
through lower holes and push fully back into place and secure. Note if the fire opening /
hearth are not level remedy this, or alternatively pack under the appliance base to
prevent the top of it leaning away from the fireplace.
6.8
Fully purge pipes of air and any debris and connect the gas supply to the 8mm elbow on
the fire. Leak test the supply using an approved method.
Note: An isolating valve must be
situated near the appliance for servicing.
6.9
Total Control Receiver Unit (if required).
Connect the cables from the valve to the receiver as shown. Keep the cables clear of the
underside of the tray. Do not force the valve cable plug when inserting into the receiver –
it only fits one way.
HT
Lead
SW
)
(yellow
TC
(
)
red
Valve
Cable
Fit four AA (1.5V) batteries into the receiver unit and the PP3 (9V) battery into the
transmitter (hand set). Connect HT lead to receiver & terminal on the pilot assembly. Fold
the heat shield as per folding instructions supplied and position it over the receiver.
6.10
Site the thermostat bulb at a suitable position where it will sense the room temperature.
(It is wrapped around the thermostat knob for transit purposes only). We recommend
that the sensing bulb is placed on the hearth behind the fret, but out of direct radiated
heat from the fire. It can be moved into the room for more accurate sensing if required.
View of Cable end
Screw
Cable
Fixing Cable
Spacer
Bracke
t
Eyebolt
Cavity box