Page 5 of 20
MANUAL CONTROL
1.8
There are 2 control knobs on the appliance. The right hand one controls On/Off and
pilot/main burner. The left hand one is the comfort level thermostat which turns the
fire down once the indicated temperature is reached. If during use the pilot is alight
but the main burner is not lit, check the thermostat position and if necessary select a
warmer setting. The range of the thermostat is around 13
o
C – 45
o
C.
Thermostat knob Ignition knob
1.9
To light the fire, first ensure the right hand control (Ignition) knob is turned clockwise
to OFF, and then press the knob for several seconds then turn slowly anticlockwise to
the ignition position. A click will be heard and the pilot (under right side of fuel bed)
should light. If it does not, repeat the operation a few times to purge any air in the
pipe. Continue to hold knob for 15 – 20 seconds to establish the pilot and then
release. If the pilot fails to establish, turn off, wait 1 minute then repeat lighting
procedure. Once the pilot has been established rotate the knob counter clockwise
towards the larger flame symbol to light the main burner. If no gas comes through to
the main burner, rotate the left hand knob (thermostat) to a hotter room setting and
the fire will light. Pilot burner position
Main burner position
Main burner operational & thermostatically controlled
1.10
To turn the fire off, rotate the right-hand knob fully clockwise back to its OFF position.