background image

Page 8 of 20 

GENERAL REQUIREMENTS 

3.1

 

Gas appliances must be installed in accordance with the rules in force. In the UK it is the 
law that all gas appliances must be installed by a Gas Safe™ registered installer (formerly 
CORGI),  in  accordance  with  the  Gas  Safety  (Installation  and  Use)  regulations  (as 
amended). The installation must also be in accordance with the relevant parts of local and 
national  building  regulations  and  in  accordance  with  BS5871  pt4  except  where  Burley 
instructions  state  differently.  For  the  Republic  of  Ireland,  reference  should  be  made  to 
IS813 and ICP3 and any guidance notes from Bord Gais. Failure to have the fire fitted by a 
qualified person nullifies 

ALL

 guarantees. 

3.2

 

The  space  to  be  heated  must  have  a  wall  vent  of  at  least  100cm²  of  ventilation  and  an 
openable window or patio door. The vent must be positioned at least 1 metre away from 
the appliance. A vent may have been supplied with the appliance and this is the preferred 
type although it is possible to use alternatives.  

3.3

 

In the Republic of Ireland two vents of not less than 60cm² each, one not less than 1.6m 
above the other, must be installed in the room.  

3.4

 

When  providing  ventilator  openings  consideration  must  be  given  to  the  avoidance  of 
locations  where  discomfort  from  draughts  may  cause  the  user  to  block  the  openings. 
Similarly  the  possibility  of  curtains  or  furniture  blocking  ventilation  openings  must  be 
considered. 

Floor  vents,  closable window  vents  or  chimneys  are  not  suitable  means  of 

ventilation.

 

3.5

 

Working surfaces include the air outlet grille. 

3.6

 

The appliance must not be used in a room of less than 30m³ in volume. Adjoining spaces, 
not separated by a door may be included. To convert cubic feet (ft³) to cubic metre (m³) 
divide the room volume in cubic feet by 35.3. 

3.7

 

The  appliance  must  not  be  installed  in  high  rise  blocks  of  flats,  bed  sitting  rooms, 
basements which are not open on at least one side, bathrooms, or bedrooms, in corridors 
stairways landing or hallways of multi occupancy dwellings, garages or rooms containing 
petroleum products. 

 

3.8

 

Soft furnishings, decorations and wall coverings etc. must not be placed within 1 metre of 
the appliance and its convection outlets (see 5.0). Be aware of curtains etc which could be 
blown towards the appliance. 

3.9

 

The  appliance  is  intended  as  a 

secondary  heat  source

.  Check  that  a  primary  source  of 

heat (such as radiators) is present in the room. If insufficient primary heat is being used 
there may be a build up of condensation, if this is the case, please warn the customer.

 

3.10

 

The appliance must not be used in rooms where the atmosphere is likely to contain water 
or chemical vapours which may adversely affect the appliance or its finish. 

3.11

 

Do not use whilst painting & decorating, or in newly decorated rooms as the residues can 
lead  to  unpleasant  smells  from  the  appliance.  Always  cover  or  have  the  appliance 
removed when decorating. (See points to note on page 14)  

3.12

 

Candles  too  close  to  the  fire  may  melt.  Scented  candles  must  be  at  least  1  metre  away 
from the appliance.  

3.13

 

Air freshener residues can enter the appliance and lead to residual odours, especially the 
plug in type. 

3.14

 

The catalyst is not an air cleaner and presence of odours is unlikely to be catalyst failure.

 

3.15

 

Houses  with  warm  air  heating  systems,  solid  walls,  or  no  damp  proof  course  may  be 
unsuitable for flueless appliances. 

3.16

 

This appliance does not contain asbestos. 

3.17

 

The  oxy  pilot  can  become  blocked  by  fibres  from  new  carpets  and  pet  hairs  advise  the 
customer to vacuum around the pilot on a regular basis to prevent blockage to pilot unit. 

Содержание EMPATHY

Страница 1: ...ONS WITH THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4240Inst G20 31 Issue March...

Страница 2: ...ST EVERY SINGLE GAS FIRE IT PRODUCES BURLEY IS IN THE UNIQUE POSITION OF KNOWING THAT EVERY APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER Fireguards A fireguard is not supplied with this appli...

Страница 3: ...l should cease and be replaced with the ticking sound of the spark igniter When the pilot flame is lit the igniter will stop another acoustic signal will confirm the pilot has been established if the...

Страница 4: ...ceiver unit to its original position REPLACE THE HEATSHIELD over the unit Press here and slide down CAUTION With the exception of battery replacement the battery holder must be located within the heat...

Страница 5: ...urn slowly anticlockwise to the ignition position A click will be heard and the pilot under right side of fuel bed should light If it does not repeat the operation a few times to purge any air in the...

Страница 6: ...ift the control lever to the top of its travel 6 The off position on the side of the fire may not correspond exactly with the control lever This is only intended as an indication 1 12 Battery Replacem...

Страница 7: ...the carton for damage before unpacking If it is obviously damaged consult the supplier as to whether to proceed with the installation 2 2 Make sure the carton is stood upright and open the top Remove...

Страница 8: ...cubic feet ft to cubic metre m divide the room volume in cubic feet by 35 3 3 7 The appliance must not be installed in high rise blocks of flats bed sitting rooms basements which are not open on at l...

Страница 9: ...o SPACERKIT and can stand directly against a wall Care should be taken with wall coverings as it may discolour them over time 4 3 The fire comes with a 60mm spacer fitted to the front trim we recommen...

Страница 10: ...from the cavity causing heat build up on the fire surround back panel or moisture ingress from the cavity 4 12 Any under grate draught devices must be sealed off 4 13 If using the fire in a hole in t...

Страница 11: ...tags clip onto the enamelled glass rails 6 4 DO NOT ATTEMPT TO USE THE APPLIANCE WITH BROKEN DAMAGED GLASS OR COALS Contact our service department 01572 756956 6 5 Decide upon the route for the gas su...

Страница 12: ...ay Do not force the valve cable plug when inserting into the receiver it only fits one way HT Lead SW yellow TC red Valve Cable Fit four AA 1 5V batteries into the receiver unit and the PP3 9V battery...

Страница 13: ...on every other gas appliance in the house and re check the pressure The pressure must still be within the tolerance of 1mb Now turn off all the other gas appliances and turn the fire down to pilot on...

Страница 14: ...atures 13 o c 45 o c but for more accurate monitoring of room temperature it is advised that the sensing bulb is removed from the fire and carefully moved to a cooler location up to 1 metre away takin...

Страница 15: ...e burner assembly in the chassis Remove the burner tray and examine it for general condition Discolouration of the burner surface is normal Clean around the air inlet removing all lint in the area of...

Страница 16: ...the manufacturer See the additional information on testing 11 PARTS LIST Part Part No Front Ceramic Coal COA4241F Rear Ceramic Coal COA4241B Oxypilot NG Check if SIT or Seagas Oxypilot LPG Check if SI...

Страница 17: ...as efficient as it was when brand new Burley manages to achieve this by designing the fire to ensure that the catalytic converter is in exactly the right position for long life and maximum efficiency...

Страница 18: ...y gas appliance must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a Gas Safe registered installer formerly CORGI or our own e...

Страница 19: ...t is important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncert...

Страница 20: ...iglo fires are protected by UK patents 2193802 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 725570 Fax 01572 724390 www burley co uk...

Отзывы: