160
Replacement of Components and Modules
Procedure:
→
Open the housing following the instructions in chapter
“8 Opening and Closing the Housing”
→
If necessary, mark the electrical connections to ensure correct assignment during reinstallation.
→
Loosen the electrical connections.
→
Loosen the connecting screws (Torx T10) for the corresponding valve module.
→
Take out the valve module and replace it with the spare part set.
→
When inserting the valve module, make sure that the form seal fits correctly and fully on the lower side of
the respective valve flange!
→
Fix the valve module: to do this, insert the screws (Torx T10) into the existing threading by turning them
backwards and tighten them to a torque of 1.2 Nm.
→
Reattach the electrical connections.
(If other connections, apart from the solenoid valve connections, have been removed, read the corre
-
sponding chapters on the electrical installation of the respective voltage / bus / connection variant)
→
Close the housing following the instructions in chapter
“8 Opening and Closing the Housing”
.
24.4
Changing the position measuring system
The position measuring system consists of a housing, with a PCB mounted above with LEDs and light con
-
ductor. There are 4 snap-fit hooks, which secure the position measuring system in the lower housing part, by
snapping them into place.
PCB with LEDs and light conductor
(device status LED / Top LED)
Housing of the position
measuring system
Snap-fit hooks (4x)
Fig. 53: Position measuring system