background image

I Englsih

secuENTRY HOME 5000 CYL

Cylinder unit power supply

2x Mignon LR6 AA Alkaline

Permitted ambient conditions

-15 °C/+50 °C / up to 95 %  

relative humidity (non-condensing)

Radio standard

Bluetooth 5.2

Range

Approx. 4 m

Number of access media

1 user code

*

 + 5 sE-Keys

**

 or 5 KeyApp 

connections

*

    User code as opening medium can only be used in conjunction with the 

PIN keypad 

ENTRY 7711 Keypad PIN 

(available as an option).

**

  Radio key ENTRY sE-Key 7713 available as an option.

Fig. 4

Fig. 6

Fig. 7

Fig. 2

Fig. 3

Fig. 5

Technical details

QR code/Administrator code

secuENTRY 5000 CYL commissioning

QR

The QR code (I) is required later when setting up 

the cylinder using the BURG-WÄCHTER KeyApp 

(Fig. 2).

The cylinders are delivered with a factory-

assigned random administrator code (II), 

therefore a code change is not mandatory (Fig. 2).

To setup the secuENTRY 5000 CYL, you 

must first download the secuENTRY 

KeyApp. This can be found in the App 

Store and Google Play Store (Fig. 3).

Once you have successfully registered, 

you can start setting up the secuENTRY 

5000 CYL. 

Open the main menu (Fig. 4).

In the following menu, tap on 

"Device 

Setup"

 (Fig. 6). From here you can add 

and setup secuENTRY units to the app.

Use the selection menu displayed and 

tap on 

"secuENTRY Profily Cylinder"

 to 

setup your secuENTRY cylinder (Fig. 7).

Tap on the menu item 

"secuENTRY setup"

 (Fig. 5).

A list is displayed in which cylinders 

that have already been registered can 

be found at a later date. This list is, 

of course, empty when installing the 

secuENTRY KeyApp and setting up a 

cylinder for the first time.

Add a new cylinder by tapping on the 

"+" in the top right-hand corner 

(Fig. 8).

Attention:  

The QR code and the factory-assigned 

administrator code are not stored by 

BURG-WÄCHTER. Recovery is not possible 

if the codes are lost. Please store the sticker 

shown above in a safe place. In addition, it is 

recommended that you take a photo of the 

sticker and archive it digitally.

secuENTRY 

KeyApp

1

2

3

4

5

6

7

Fig. 8

Set contents

I

 ENTRY Home 5000 CYL Cylinder

II

 Forend screw

III

 Hexagon spanner SW2

IV

  Quick Start Guide plus  

warranty and  

disposal instructions

!

Fig. 1

I

II

Fig. 1

I

II

III

IV

Содержание secuENTRY Home ENTRY 5000 CYL

Страница 1: ...sured in the centre of the forend screw No drilling or laying of cables is required and it is ideally suited for both new installations and retrofitting The secuENTRY 5000 CYL can be fitted to house and interior doors The secuENTRY 5000 CYL is setup and operated using the free smartphone app secuENTRY KeyApp The transmission is wire less the cylinder uses the modern Bluetooth 5 2 standard Alternat...

Страница 2: ...you have successfully registered you can start setting up the secuENTRY 5000 CYL Open the main menu Fig 4 In the following menu tap on Device Setup Fig 6 From here you can add and setup secuENTRY units to the app Use the selection menu displayed and tap on secuENTRY Profily Cylinder to setup your secuENTRY cylinder Fig 7 Tap on the menu item secuENTRY setup Fig 5 A list is displayed in which cylin...

Страница 3: ...iately during setup tap on CONTINUE II Fig 13 for the corresponding request This then leads directly to the Change administrator code function which is also described in the following chapter on page 3 at point 5 Your secuENTRY cylinder is now fully setup It will now appear in the list of setup cylinders Fig 14 8 9 10 11 12 13 14 P QR I I II II Proceed as follows to delete a cylinder Open the main...

Страница 4: ...been created is displayed Create a new user by tapping on the in the top right hand corner Fig 29 1 2 3 4 Fig 28 Fig 29 Fig 26 Fig 27 Create user and assign access medium There are various access media available to open your door Including opening with a user defined code the sE Key radio key and the KeyApp itself Once you have created a secuENTRY cylinder in the KeyApp you are the administrator o...

Страница 5: ...n assigned the user code and the selected lock within the KeyApp Fig 31 The programming process must be started so that the cylinder also receives this information The corresponding description can be found in the chapter Programming Updating the cylinder on page 9 I I II II III Create user Radio key sE Key 1 2 3 4 Fig 32 Fig 34 Fig 33 Fig 35 Note The radio key ENTRY sE Key 7713 is available separ...

Страница 6: ...39 after which a QR code is dis played on the entire screen Leave the QR code displayed on the screen and put the smartphone B aside for a moment The next steps are performed on smartphone A 1 2 3 4 5 Smartphone A The QR code displayed on smartphone B can now be scanned via the app on smartphone A Tap the QR code symbol in the Enter KeyApp line in the user menu Fig 40 You may be asked to confirm t...

Страница 7: ...eceived from smartphone B on smartphone A The file can be deleted again after programming Tap on CSV in the user menu at the top right Fig 49 Select the CSV file that you received by email from smartphone B I Confirm the selection at the top right with the tick Fig 50 The data is now recorded in the KeyApp Next assign a cylinder by tapping it in the list of cylinders already registered and save yo...

Страница 8: ...ired enter a new user defined code I Fig 57 Tip The entry is concealed Tap the eye symbol on the right side to visualise and check the entry Attention Do not select simple codes that are easy to guess e g 1 2 3 4 5 6 Also do not select any personal infor mation e g birthdays or other infor mation that can be easily be deduced by persons who know the user Save your settings by tapping the disk symb...

Страница 9: ...ETE field II that appears on the right Fig 63 3 4 Fig 62 Fig 63 Fig 60 Fig 61 Programming updating the cylinder The cylinder must be programmed accordingly so that the registered users can now open the lock with the stored opening options Program the cylinder as follows Open the main menu Fig 64 Tap on the menu item secuENTRY setup Fig 65 Tap on Programming in the submenu Fig 66 The list of progra...

Страница 10: ... from step 6 9 10 12 13 14 15 11 Fig 73 Fig 75 Fig 74 Fig 71 Fig 72 I I II II Opening the secuENTRY lock Fig 76 Proceed as follows to open the ENTRY Home 5000 CYL cylinder and consequently also the door Open the secuENTRY KeyApp and press the GET ACCESS button in the middle Fig 76 Note The secuENTRY KeyApp is programmed so that when more than one cylinder is used it automatically adjusts to the cy...

Страница 11: ...data is now retrieved from the cylinder and stored in the app as a log file Fig 84 1 2 3 4 5 7 6 Fig 81 Fig 83 Fig 82 Fig 84 Fig 79 Fig 80 After retrieval a confirmation message appears which you confirm with OK Fig 85 Go back one step in the menu and tap on the item Lock history Fig 86 A list of cylinders with retrieved log files appears Select the required cylinder Fig 87 The menu of the selecte...

Страница 12: ...ation of the secuENTRY 5000 CYL is explained below Prior to installation please read the installation instructions carefully Remove the existing door lock cylinder by loosening the forend screw in the door and pulling out the cylinder with the key inserted Fig 90 Remove the two hexagonal screws in the two knobs with the enclosed hexagonal spanner Fig 91 Pull off the knob on the outside completely ...

Страница 13: ...age 14 of this manual Insert two new batteries Make sure that the polarity is correct according to the drawing Fig 99 Replace the front cover and screw it on tightly Fig 100 Fig 97 Fig 101 Fig 102 2 3 4 1 Fig 98 Fig 99 Fig 100 Whether for one front door several doors or a complete locking system Simply configure your individual unit with the secuENTRY modular system Your ENTRY HOME 5000 CYL cylind...

Страница 14: ...to dispose of this device at any time please remember that many components of this device contain valuable materials that can be recycled Printing and typesetting errors as well as technical changes reserved Please note that electrical and electronic devices as well as batteries must not be disposed of with household waste but rather apart from it or separately Please obtain information on the col...

Страница 15: ...www burg biz BURG WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany www burg biz ENTRY HOME ENTRY 5000 CYL BD Main Instruction Manual ENTRY 5000 CYL EN HBG SWI 040422 ...