35
J1
SOLENOID VALVE (DISPENSE) - FMD-1 & FMD-2
FIG. 36 DISPENSE SOLENOID VALVE
Location:
The dispense solenoid is located on the upper
left center of the tank.
Test Procedures:
1. Disconnect the dispenser from the power source.
2. For FMD-1 disconnect the red and white wires from
the solenoid valve. For FMD-2 disconnect orange
and white wires on the right solenoid or the tan and
white wires on the left solenoid. With the “RINSE/
RUN” switch in the “RINSE” upper position press
the dispense switch on front of the door.
3. Check the voltage across the red and white, orange
and white or tan and white wires with a voltmeter.
Connect the dispenser to the power source. The
indication must b:
a) 120 volts ac for two wire 120 volt models,
b) 120 volts ac for three wire 120/208 volt or 120/240
volt models,
c) 230 volts ac for two wire 230 volt models, after a
delay of approximately 5 seconds.
4. Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to wiring
diagram and check dispenser wiring harness.
5. Check for continuity across the solenoid valve coil
terminals.
If continuity is present as described, reconnect the wires
to the solenoid (see Fig. 37), proceed to #6
If continuity is not present as described, replace the
solenoid valve.
6. Check the solenoid valve for coil action. Connect
the dispenser to the power source. With “RINSE/
RUN” switch in the “RINSE” upper position press the
dispense switch and listen carefully in the vicinity of
the solenoid valve for a “clicking” sound as the coil
magnet attracts.
7. Disconnect the dispenser from the power source.
If the sound is heard as described and water will not pass
through the solenoid valve, there may be a blockage in
the water outlet before the solenoid valve or, the solenoid
valve may require inspection for wear, and removal of
waterborne particles.
If the sound is not heard as described, replace the so-
lenoid valve.
Removal and Replacement:
1. Open dispenser door and remove the hopper(s)
2. Remove the two #8-32 screws securing the hopper
panel to the auger motor mounting panel and two
#8-32 screws to the whipper mounting panel. Remove
panel and set aside.
P1666
SERVICE (cont.)
FMD-1
FMD-2
P1665
29112 091307