TROUBLESHOOTING (cont.)
PROBLEM
Product overflows container
Weak product
PROBABLE CAUSE
1. Dispense Switch
2. Dispense Solenoid Valve
1. Water Temperature
2. Whipper Motor
3. Frother
4. Dispense Solenoid Valve
5. Auger Drive - FMD-1
Auger Drive - FMD-2
6. Auger Spring - FMD-1
Auger Spring - FMD-2
7. Auger Motor - FMD-1
Auger Motor - FMD-2
8. Rinse/Run Switch - FMD-1
Rinse/Run Switch - FMD-2
9. Rinse Timer - FMD-2
REMEDY
Refer to Service - Dispense Switch for
testing procedures. See page 22
Remove the solenoid valve and clear
any obstructions. Rebuild or replace
the valve if necessary. See page 35
Place an empty container beneath the
dispense tip. Initiate a dispense cycle
and check the water temperature im-
mediately below the dispense tip with
a thermometer.
Reading for mechanical thermostat
models should be 180°F to 200°F (see
thermostat temperature settings decal
in USER NOTICES on page 3.)
Refer to Service - Whipper Motor for
testing procedure. See page 25
Refer to Service - Frother Compo-
nents. See page 25
Refer to Service - Dispense Solenoid
Valve for test procedures. See page
35
Refer to Service - Auger Drive Com-
ponents. See page 13
See page 15
Refer to Service - Auger Drive Com-
ponents. See page 13
See page 15
Refer to Service - Auger Drive Com-
ponents. See page 13
See page 15
Refer to Service - Rinse/Run Switch
for test procedures. See page 31
See page 33
Refer to Operation - Rinse Timer.
See Page 5