37
J1
TANk HEATER - FMD-1 (shown) & FMD-2
FIG. 40 TANK HEATER
Location:
The tank heater is located inside the tank and
secured to the tank lid.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Check the voltage across the black and white wires
120 volt or 230 volt models or black and red wires
for 120/208 volt models or 120/240 volt models
with a voltmeter. Connect the dispenser to the power
source. The indication must be:
a) 120 volts ac for two wire 120 volt models,
b) 120 volts ac for three wire 120/208 volt or
120/240 volt models,
c) 230 volts ac for two wire 230 volt models, after
a delay of approximately 5 seconds.
3. Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the dis-
penser wiring diagram and check the wiring harness.
4. Disconnect the black wire and the white or red wire
from the tank heater terminals.
5. Check for continuity across the tank heater termi-
nals.
If continuity is present as described, reconnect the
wires, the tank heater is operating properly.
If continuity is not present as described, replace the
tank heater.
P1665
P1217
FIG. 39 INLET SOLENOID VALVE TERMINALS
SERVICE (cont.)
SOLENOID VALVE (INLET) - FMD-1 & FMD-2
(cont.)
WHI from Main Harness
7. Disconnect the dispenser from the power source.
If the sound is heard as described and water will not
pass through the solenoid valve, there may be a block-
age in the water line before the solenoid valve or, the
solenoid valve may require inspection for wear, and
removal of waterborne particles.
If the sound is not heard as described, replace the
solenoid valve.
Removal and Replacement:
1. Remove the white and violet wires from the solenoid
valve.
2. Turn-off the water supply to the dispenser.
3. Disconnect the water lines to and from the solenoid
valve.
4. Remove the two #8-32 screws securing the sole-
noid to the rear of the dispenser housing. Remove
solenoid.
5. Remove the two #8-32 U-Type fasteners from the
solenoid bracket.
6. Install the two #8-32 U-Type fasteners and the two
#8-32 screws on the new solenoid.
7. Install new solenoid on rear of dispenser housing
and tighten the two screws
8. Securely fasten the water lines to and from the
solenoid valve.
9.Refer to Fig. 39 and reconnect the wires.
VIO from Main Harness
29112 091307