21
SERVICE (cont.)
6. Disconnect the four pin connector from J4 of the
control board.
7. Check the voltage across pins 1 & 4 of the four pin
connector on the wiring harness with a voltmeter.
Connect the dispenser to the power source. The
indication must be:
a) 120 volts ac for two wire 120 volt models.
b) 120 volts ac for three wire 120/208 volt or
120/240 volt models.
c) 230 volts ac for two wire 230 volt models.
8. Disconnect the dispenser from the power source.
If voltage is present as described, proceed to step 9.
If voltage is not present as described, refer to the wiring
diagram and check the dispenser wiring harness.
9. Reconnect the four pin connector of the wiring
harness to J4 of the control board.
10. Disconnect the ten pin connector from J2 of the
control board.
11. Carefully connect a piece of insulated jumper wire
to pin 10 (top right) of J2 on the control board.
Keep the other end of this wire away from any metal
surfaces of the dispenser.
12. Check the voltage across the terminals of the inlet so-
lenoid valve with a voltmeter. Connect the dispenser
to the power source. The indication must be:
a) 120 volts ac for two wire 120 volt models,
b) 120 volts ac for three wire 120/208 volt or
120/240 volt models,
c) 230 volts ac for two wire 230 volt models, after
a delay of approximately 10 seconds.
13. Touch the free end of the jumper wire to the dis-
penser housing. The indication must be 0.
14. Move the jumper wire away from the housing. The
indication must, again, be:
a) 120 volts ac for two wire 120 volt models,
b) 120 volts ac for three wire 120/208 volt or
120/240 volt models,
c) 230 volts ac for two wire 230 volt models, after
a delay of approximately 5 seconds.
15. Disconnect the dispenser from the power source
and remove the jumper wire.
If voltage is present as described, proceed to step
16.
If the voltage is not present as described, replace the
control circuit board.
16. Reconnect the ten pin connector of the wiring
harness to J2 of the control board.
17. Gently pull the liquid level probe out of the tank lid
and inspect for corrosion. Replace it if necessary.
18. Place the probe so that neither end is in contact
with any metal surface of the dispenser.
19. Check the voltage across the terminals of the inlet so-
lenoid valve with a voltmeter. Connect the dispenser
to the power source. The indication must be:
a) 120 volts ac for two wire 120 volt models,
b) 120 volts ac for three wire 120/208 volt or
120/240 volt models,
c) 230 volts ac for two wire 230 volt models, after
a delay of approximately 10 seconds.
20. Move the probe’s flat end to the dispenser housing.
The indication must be 0.
21. Move the probe’s flat end away from the housing.
The indication must, again, be:
a) 120 volts ac for two wire 120 volt models,
b) 120 volts ac for three wire 120/208 volt or
120/240 volt models,
c) 230 volts ac for two wire 230 volt models, after
a delay of approximately 5 seconds.
22. Disconnect the dispenser from the power source.
If the voltage is present as described, re-install the
probe. The liquid level control circuitry is operating
properly.
If the voltage is not present as described, check the pink
probe wire and green tank wire for continuity.
Hopper Motor Control Circuitry:
1. Disconnect the dispenser from the power source.
2. Disconnect the six pin connector from J3 of the
control board.
3. Check the voltage across pins 5 & 6 of the six pin
connector on the wiring harness with a voltmeter.
Connect the dispenser to the power source. The
indication must be 24 volts ac.
4. Disconnect the dispenser from the power source.
If voltage is present as described, proceed to step 5.
If voltage is not present as described, refer to the wiring
diagram and check the dispenser wiring harness.
5. Reconnect the six pin connector of the wiring har-
ness to J3 of the control board.
6. Check that the rinse/run switch is in the run posi-
tion.
29112 091307