9
TROUBLESHOOTING (cont.)
PROBLEM
Product will not dispense (cont.)
Water is not hot
PROBABLE CAUSE
5. Solenoid Valve (Inlet)
6. A) Level Control Board and Probe
- FMD-1
B) Control Board and Probe -
FMD-2
7. A) Auger Drive - FMD-1
B) Auger Drive - FMD-2
8. Water Strainer
9. Lime build-up
CAUTION -
Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up on
stainless steel surfaces can initiate
corrosive reactions resulting in seri-
ous leaks.
10. Transformer - FMD-2
1. Limit Thermostat
CAUTION -
Do not eliminate or by-
pass limit thermostat. Use only BOM
replacement part #29329.1000
2. Control Thermostat
3. Tank Heater
REMEDY
Refer to Service - Solenoid Valve
(Inlet) for testing procedures. See
page 36
Refer to Service - Level Control Board
and Probe for testing procedures.
See page 30
Refer to Service - Control Board
and Probe for testing procedures.
See page 20
Refer to Service - Auger Drive. See
page 13
Refer to Service - Auger Drive. See
Page 15
(A) Direction of flow arrow must be
pointing towards dispenser.
(B) Remove the strainer and check
for obstructions. Clear or replace.
Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.
Refer to Service - Transformer for
testing procedures. See page 39
Refer to Service - Limit Thermostat
for testing procedures. See page
32
Refer to Service - Control Ther-
mostat for testing procedures. See
page 19
Refer to Service - Tank Heater for
testing procedures. See page 37
29112 051200