TROUBLESHOOTING (cont.)
PROBLEM
Water is not hot (Cont.)
Spitting or excessive steaming
Dripping from dispense tip
Water flows into tank continuously
PROBABLE CAUSE
4. Tank Heater Switch
1. Lime build-up
CAUTION -
Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up on
stainless steel surfaces can initiate
corrosive reactions resulting in seri-
ous leaks.
2. Control Thermostat
1. Lime build-up
CAUTION -
Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up on
stainless steel surfaces can initiate
corrosive reactions resulting in seri-
ous leaks.
2. Dispense Solenoid Valve
1. A) Level Control Board and Probe
- FMD-1
B) Control Board and Probe -
FMD-2
2. Solenoid Valve (Inlet)
REMEDY
Refer to Service - Tank Heater
Switch for testing procedures. See
page 38
Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.
Refer to Service - Control Thermo-
stat for testing procedures. See
page 19
Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.
Remove the dispense solenoid valve
and clear any obstructions. Rebuild
or replace the valve if necessary.
See page 35
Refer to Service - Level Control Board
and Probe for testing procedures.
See page 30
Refer to Service - Control Board
and Probe for testing procedures.
See page 20
Refer to Service - Solenoid Valve
(Inlet) for testing procedures. See
page 36