TeraStation III iSCSI User Manual
58
Errors and Warnings
Displays the current status when changing the settings or formatting drives.
Examples of LCD
Meaning
SYSTEM Error
E00
MPU No Response
The system is not responding. Disconnect power for 10 seconds, then reattach
and boot the TeraStation. If the error persists, contact tech support.
DRAM LINES
E01
DATA Failure
IC error. Contact tech support.
DRAM LINES
E02
ADDRESS Failure
IC error. Contact tech support.
RTC Chip
E03
No RTC Clock
Clock error. Disconnect power for 10 seconds, then reattach and boot the
TeraStation. If the error persists, contact tech support.
SYSTEM Error
E04
Can't Load Krnl!
The firmware is corrupted. Contact tech support for assistance.
WDT
E05
SYSTEM Stopped
System hung. Disconnect power for 10 seconds, then reattach and boot the
TeraStation. If the error persists, contact tech support.
TFTP MODE
E06
Lost boot image
The firmware is corrupted. Wait for 5 minutes. If "E04" appears on the display,
turn off the unit. Contact tech support for assistance.
HD ALL E07
ALL HD Not Found
Hard disks are not found. If the drives are installed but this message appears,
contact Buffalo’s tech support for assistance.
UPS
E10
Dependent Mode
Power outage. The TeraStation is running on UPS battery power and will be shut
down safely.
SYSTEM I10
TOO HOT!
System temperature is above safe limits. Move the TeraStation to a cooler place.
Do not place anything too close to the TeraStation that might block airflow.
SYSTEM Error
E11
Fan Failure
The fan is not spinning. Check for dirt or objects caught in fan. Remove any
debris with tweezers or canned air. If the error persists, contact tech support.
SYSTEM Error
E12
Cooling Failure
System temperature is above safe limits. Move the TeraStation to a cooler place.
Do not place anything too close to the TeraStation that might block airflow.
RAID Error
E13
ARRAYx Error
An error has occurred in the Xth RAID array. The system will run in degraded
mode if RAID1 or RAID5 is used. For best results, test the drives individually and
replace the defective drive.
RAID Arrayx
E14
Can't Mount
The Xth RAID array could not be mounted. Turn off the TeraStation, then reboot
it. If the error persists, rebuild the RAID array. If the error still persists, contact
Buffalo’s tech support for assistance.
HDx Error
E15
Many Bad Sectors
The bad sectors in the Xth hard drive have become serious. Replace the drive.
HDx Error
E16
HDx Not Found
Cannot find the Xth hard drive. The Xth hard drive may not be connected or may
be damaged. Check the drive and replace if necessary.