TeraStation III iSCSI User Manual
51
RAID Scanning
Click [Modify Settings]
to change settings.
RAID Scanning
A RAID scan read checks all sectors in the data area of drives in an array. If a bad sector
error is found during the scan, it is repaired automatically. Note that some kinds of
errors are repaired automatically by the array even without a RAID scan.
Status
Descriptions
repair possible
• Read error in the data area which are build in RAID 1, 5, or 10 (in-
cluding RAID 1 system array.)
impossible to repair
• Write Error
• RAID management area error
• Drive partition information area error
• Drive recognition failure, etc.
• If many repairable errors are found in one of hard drive which build RAID, that drive is
removed from the RAID, the system will automatically move to degraded mode. The
system will continue to function, but data is not protected in degraded mode, so it is
strongly recommended to immediately replace the erroneous hard drive.
• When running RAID Scanning for the first time, it is strongly recommended to back up
your data on TeraStation in advance.
[RAID Scanning]:
Set whether using RAID Scanning or not.
[RAID Scanning Schedule]:
Select the schedule to perform RAID Scanning.
• [Every Week], and from [Sunday] to [Saturday]
• [1st], and from [Sunday] to [Saturday]
• [2nd], and from [Sunday] to [Saturday]
• [3rd], and from [Sunday] to [Saturday]
• [4th], and from [Sunday] to [Saturday]
• [1st, 3rd], and from [Sunday] to [Saturday]
• [2nd, 4th], and from [Sunday] to [Saturday]
• [Every 1st day/month]
Select [Begin Immediate RAID Scan] and click [Save] to immediately run RAID Scanning.
[RAID Scanning Start Time]:
Select the time to start RAID scans from 0 to 23 o'clock.
To stop a RAID scan, click [Abort RAID Scanning].