XT-Micro Control Panel
8
Program
Miscellaneous
Cell Eff 90*
RAS 3*
Aux config 3*
Off 20 On 60
Parameter Description
10/22/09 13:10
Refig Ramp
Shows date, time and panel mode of operation. No programmable values. The left side
of the bottom line is the main mode and the right side is the secondary mode.
Daily RT (system run time since noon) 2.6 hrs
Version 00.03 software version 0.03
Daily RT 2.6
Version 00.03
(Programmable Parameter)
Total Run Time in hours for the year. Clear once a year. Choose Yes to clear time.
Total RT 340.0
Clear? N/Y
(Programmable Parameter)
Unit # is the panel number when used in a network with multiple panels. Each panel
must have a unique number.
Unit # 1 *
(Programmable Parameter)
Temp SP (temperature setpoint) This is the desired plenum temperature setpoint. Press
the ENTER button to change the setpoint.
Plenum is the current plenum temperature. The plenum temperature is the average of
two plenum sensors. The two sensors are located on J7 and J10.
Temp SP 65.0*
Plenum 65.6
Return is the temperature of the return air and is on terminals 1&2 of J11.
Pile 1 is the temperature sensor located on pins 3&4 of J15.
Return 66.0
Pile 1 66.0
Pile 2 is the temperature sensor located on pins 3&4 of terminal J18.
Pile 3 is the temperature sensor located on pins 1&2 of terminal J18.
Pile 2 66.0
Pile 3 66.0
Door Pos is the position of the fresh air doors in percent.
Ref Out is the refrigeration output in percentage.
Door Pos 0
Ref Out 100
2.2
AOM Switches
Fan
Auto *
Refrig Switch
Manual 25%*
Cavity Switch
Auto *
Door Switch
Auto *
Clima Switch
Off *
Humid Switch
Manual *
Heat
Auto *
Aux
Off *