Heat Switch
Auto *
Aux Switch
Off *
The Heat Switch has three positions, Off, Manual and Auto. In the off position the heat
will not turn on. In the Manual position the return air heat will be on all the time the Stop /
Start switch is in Start. In the Auto position the return air heat will turn on and off when
needed. This is a programmable function and can be changed by pressing the Enter
button.
Aux Switch. The Aux switch can be used for any type of addition control. It has three
positions, Off, Manual and Auto. In the off position the Aux output will not turn on. In the
manual position the Aux output will turn on any time the Stop / Start switch is in the Start
position. In Auto the Aux switch will turn on and off when needed. To change press the
Enter button.
Climacell
Man *
Climacell is the BTU name for the evaporative cooling cell. This screen shows the status
of the cell. The Cell can be off, auto or manual. In manual the cell will run any time the
fans are running. In off, the cell will not run. In auto the cell can be used to control hu-
midity. To change modes, press the ENTER button and use the up and down arrows to
change the mode.
Humidity
Auto *
Humidity refers to the Hum 1 output. This is used to turn on and off the water pump for
the humidifier. The spinner will run all the time. The Hum 1 output has three modes.
Off, Auto and Manual. In Off the humidifier will not run at all. In Manual the humidifier
will run when ever the fans are on. In Auto the Hum 1 output will go on and off to main-
tain plenum humidity. To change modes, press the ENTER button and use the up and
down arrows to change the mode.