Operation
- 3.6 -
SMART KNIT
IS3 Sensors Features
The
IS3
electronic sensors are capable of detecting, thanks to a patented and
advanced control technology, the image variation of a moving yarn under control;
it can show with absolute certainty the actual movement or stop condition of the
yarn. The technique based on image variation
(Image Smart Scanning Sensor),
makes the
IS3
sensor exempt from the influence of environment/yarn conditions:
i.e. humidity, conductivity and machine vibrations. It does not require any physical
contact with the yarn under control and therefore it allows a perfect monitoring
without affecting the tension features of the yarn itself, in any way.
The
IS3
devices are the most reliable and advanced solution for yarn control on
textile machines.
IS3
is fully programmable for an easy adaptation to the control of any type of
yarn/application.
Optical interface of IS3 sensors
The
IS3
sensors have two signaling lights
(green LED, red LED)
and a “Touch
Light” optical button.
During the automatic numbering of the sensors
(flashing green LED),
touch the
optical button to give the sensor the number shown in the devices configuration
screen.
Interpretation of the sensor signaling lights
Green LED ON
Normal operation, the yarn is running inside the sensor;
No technical fault detected by the sensor.
Red LED ON
Yarn stopped.
Green LED FLASHING
The system is in automatic numbering phase.
Red LED FLASHING
During machine operation the sensor has detected a
fault.
(BROKE: broken yarn - UNCUT: uncutted yarn).
Green LED ON
Red LED ON
Stopped sensor. Switch off, then switch on the system. If
the condition is permanent, replace the sensor.
Green LED FLASHING
Red LED FLASHING
Indicates a technical fault in the sensor
(e.g. a loss of
stored data).
Try to reprogram the sensor. If the fault
remains, replace the sensor.
Green led
Touch
light
Red led
Содержание IS3F-485
Страница 1: ...SMART KNIT IS3F 485 YARN CONTROL SYSTEM Operating Manual Rev 1 0 January 2006 ENGLISH ...
Страница 6: ...Introduction I 2 SMART KNIT Page intentionally left blank ...
Страница 11: ...Technical Data and Installation SMART KNIT 2 3 SM DIN Modules Interconnection ...
Страница 38: ...Operation 3 26 SMART KNIT Page intentionally left blank ...
Страница 44: ...Troubleshooting and Maintenance 4 6 SMART KNIT Page intentionally left blank ...