Operation
- 3.10 -
SMART KNIT
Preliminary operations for using the SMART KNIT Terminal
!
Just after installation and before using the system, check that all the
connectors are plugged-in properly.
Power On the system and check that the graphic display shows sequentially, for a
few seconds, the two screens shown on the left side of this page:
(Type of SMART system)
(Installed software version)
During this phase all the red Leds embedded inside the 5 buttons of
SMART
KNIT
terminal and all the red Leds of the SM-DIN Interface Modules must turn
On.
!
If the display does not light-up, then refer to “Troubleshooting”
paragraph.
If the
MACHINE >>>>>
message appears, it means that the system correctly
started the production control phase.
(All the red Leds inside the buttons of SMART
KNIT terminal, as well as the Leds of SM-DIN Interface Modules turn off, except
the CONTROL Leds).
If the ERROR RAM message appears on the screen, it means that the self-
diagnosys performed at power on has detected an error in the memory of the
SMART terminal.
Press
to continue.
!
The system will erase all settings entered by the user and will reload the
default values!!
If the error persists, please refer to “Troubleshooting” paragraph.
System
start up
Содержание IS3F-485
Страница 1: ...SMART KNIT IS3F 485 YARN CONTROL SYSTEM Operating Manual Rev 1 0 January 2006 ENGLISH ...
Страница 6: ...Introduction I 2 SMART KNIT Page intentionally left blank ...
Страница 11: ...Technical Data and Installation SMART KNIT 2 3 SM DIN Modules Interconnection ...
Страница 38: ...Operation 3 26 SMART KNIT Page intentionally left blank ...
Страница 44: ...Troubleshooting and Maintenance 4 6 SMART KNIT Page intentionally left blank ...