346260
16
T = Lock relay timer
Configurator
0
1
2
3
4
5
6
7
Time in sec.
4
1
10
20
40
60
90
180
R = Activation/deactivation of the function
Configurator
0
1
Early closing
Enabled (2 sec.)
Disabled
M = Mode management
Allocates the operating mode to the internal actuator relay according to the table:
M =
0
1
2
3
4
5
6
Access control management
YES
YES
Signal repetition
YES
YES
NO
NO
2-wire video
intercom management
NO
NO
NO
YES
YES
YES
YES
Actuator relay status
Normal open
Normally closed.
Electromagnetic
lock
Signal repetition Normal open
Normally closed.
Electromagnetic
lock
Normal open
Normal open
Notes:
If enabled, 2 seconds after the opening of the passage the relay switches, without waiting for the T time to
elapse (this function can be used with a door status magnetic contact and for T ≥ 4s).
The command engages the
NC
and
NO
contacts of the internal relay. As a consequence, even with
M = 0
, it
will be possible to use the internal relay as
Normally Closed
. In case of sector power failure (230V a.c.) the
relay remains normally open and, if the Electromagnetic locks are powered by a buffer battery, the locks
remains closed.
In this mode, the software forces the relay to operate in the opposite way (
positive security
). The
NO
contact
remains in the closed status and is open to open the door (passage). In case of sector power failure (230V a.c.)
the relay opens and, even if the Electromagnetic locks are powered by a buffer battery, the locks opens.
It works as are signal repeater. In case of system tampering or door opening, the relay output can activate
an external signalling device (acoustic or optical), based on the time value configured in T.
Integration between video control system and access control (see instructions with item 348000).
Video handset system mode (M=5, 6)
Audio or video system with power supply item 346000: cabling on the power supply.
18V 4A
A
230Va.c.
PS
BUS
TK
BUS
PI
346830
BUS PL S+ S-
BUS
PI
BUS 2
1
346000
A
BUS TK
*
S1
S2
ART. 346260
T= -5 +45°C
IP 30
C NC NO/S+ S-
- TMP PL RC
SCS
J
M
P
J
M
P
PE: P=1
P
N
T S
1
1
J
M
P
J
M
P
P
M R T J1 J2
5
A = Entrance-hall lock button
* S+ S- =
18V 4A impuls
250mA
handhaving
3 INSTALLATION
EXAMPLES