5.2 - Maintenance Routines
34
SBT-2400 Service Instructions
M2041/5en
©BTG 2006
5.2 Maintenance Routines
5.2.1
Changing O-ring Seals
5.2.1.1
Wetted Part
1. Remove the old O-ring seal from the SBT-2400.
2. Mount the new O-ring seal. Use silicon grease to keep it in place during in-
stallation.
5.2.1.2
Housing
1. Remove the blade. See section 5.3.2.1:
Remove the Blade and Deflector
.
2. Remove the housing cover.
3. Remove the circuit board. See section 5.3.3.1:
Spare parts required:
O-ring seal
Consumable required:
(Silicon grease)
Spare parts required:
O-ring seal
Tools required:
Snap ring pliers
2.5 mm allen key/hexagon spanner
4 mm allen key/hexagon spanner
(Small pliers)
(Wise)
Consumable required:
(Silicone grease)
Содержание Pulptec SBT-2400
Страница 1: ...USER MANUAL Pulptec BTG Pulp Paper Sensors AB SBT 2400 Static Blade Consistency Transmitter M2041 5en ...
Страница 12: ...1 4 Type Sign Explanation 6 SBT 2400 Product Introduction M2041 5en BTG 2006 ...
Страница 26: ...3 6 Mounting of Optional Accessories 20 SBT 2400 Installation Instructions M2041 5en BTG 2006 ...
Страница 58: ...5 4 Troubleshooting 52 SBT 2400 Service Instructions M2041 5en BTG 2006 ...