54
T419S Indicator Service Manual
6
ADMIN Menu
6.4.5 PLC
To connect to DeviceNet or Profibus option cards, don’t set up a protocol.
Net 1
This is an item for future expansion to multiple networks. This is not
available on this indicator. Continue to the next item.
Type
In this item you can choose;
Enet IP
or
M TCP
. Choose
Enet
IP
to enable Ethernet IP. Choose
M TCP
to enable Modbus-
TCP.
Endian
Choices for this item are
big
or
Little
. Default is
Little
.
Trade
This stands for word swap or trade configuration. Choices for
this item are
On
or
Off
. Default is
Off
.
In
This stands for inbound data configuration. You will first select
one of the 32 memory registers available for inbound data.
Then you will select the data type and then the network token
you want assigned to that memory register.
In 1-32
These are the 32 inbound data configuration
memory registers. For each there are three
choices: Type, Value and Scale. See the
descriptions below:
If connecting to a PLC, the E-NET configuration menu does not require any special
configuration and the Client/Server selection for TYPE setting must be set to OFF.
ENDIAN:
Big = Most Significant Byte, Least Significant Byte
Little = Least Significant Byte, Most Significant Byte
TRADE: On = WORD2,WORD1
Off = WORD1,WORD2
The PLC configuration determines the appropriate indicator settings for Endian and
Trade.
Содержание T419S
Страница 1: ...AWT35 501788 Issue AC T419S Indicator Service Manual original instructions AMERICAS CONFIDENTIAL ...
Страница 2: ...BTEK_T419S_s_en_501788 book 2019 B TEK All rights reserved ...
Страница 118: ...118 T419S Indicator Service Manual ...
Страница 130: ...130 T419S Indicator Service Manual ...
Страница 134: ...134 T419S Indicator Service Manual Last 28 Temp 28 ...
Страница 135: ......
Страница 136: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...