T419S Indicator Service Manual
6
ADMIN Menu
Con.No
This stands for connection number. Under this are
E-Net 1
through
E-Net
10
. These are the numbered Ethernet ports.
E-Net 1-10
Choose the Ethernet port to set up. Choices available under
Type x
Use this to set the type of connection;
Off
,
Client
,
S
erver
,
UDP
or
Clnt2
.
If
Type
is set to
Off
Type x
is the only item listed under
E-Net x
. You must
choose one of the other choices to see other items listed.
If
Type
is set to
Client
Type x
,
Port x
,
Host x
, and
Tmout x
are displayed.
These are explained below.
Port x
This stands for Remote Port. You need to pick
the remote port number to send messages to
and receive messages from. Key a port
number from 1 to 65535.
Host x
This is the host IP address of the server. Key
in a value from 0 to 255.
Tmout x
If no messages are received within the timout
period the socket will try to reconnect. Key in a
value in seconds from 0 to 60000. Default is 0.
If
Type
is set to
Server
Type x
and
Port x
are displayed. Allowable values for
each are listed below.
Port x
This stands for Remote Port. You need to pick
the remote port number to send messages to
and receive messages from. Key in a port
number from 1 to 65535.
If
Type
is set to
UDP
UDP stands for User Datagram Protocol.
Type x
,
Port x
,
LcPrt x
,
RxAdd x
,
TxAdd x
and
DynTX x
are displayed.
These are explained below.
Port x
This stands for Remote Port. You need to pick
the remote port number to send messages to
and receive messages from. Key a port
number from 1 to 65535.
LcPrt x
This stands for Local Port. This is the local port
that the remote IP will send messages to. Key
in a port number from 1 to 65535.
If the Ethernet port connection is to a PLC, the
Type
setting must be set to
Off
.
If
Type
is set to
Off
, it disables the selected port from communication to a server or
client on the network.
The
Client
selection is typically used when the indicator(s) is connected to a print
server or a shared printer on the network.
Host IP Address is only used if the
Type
setting is
Client
for this port connection.
Содержание T419S
Страница 1: ...AWT35 501788 Issue AC T419S Indicator Service Manual original instructions AMERICAS CONFIDENTIAL ...
Страница 2: ...BTEK_T419S_s_en_501788 book 2019 B TEK All rights reserved ...
Страница 118: ...118 T419S Indicator Service Manual ...
Страница 130: ...130 T419S Indicator Service Manual ...
Страница 134: ...134 T419S Indicator Service Manual Last 28 Temp 28 ...
Страница 135: ......
Страница 136: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...