T419S Indicator Service Manual
111
61
X
X
Freefall 2
X
62
X
X
Gross Future 1
X
63
X
X
Gross Future 2
X
64
X
X
Net Future 1
X
65
X
X
Net Future 2
X
66
X
X
Piece Weight x 1000
X
67
X
Percent Accuracy
X
68
X
X
Last Sample
X
69
X
X
Over Under Load
X
70
X
X
Act Value
X
71
X
Zero Flag
X
72
X
Tare Flag
X
73
X
Print Flag
X
74
X
Accum Flag
X
75
X
Reset Scale Flags
X
104
X
X
X
X
Accumulated Gross Weight Total
Value
X
105
X
X
Accumulated Tare Weight Total
Value
X
106
X
X
X
X
Accumulated Net Weight Total
Value
X
107
X
X
X
X
Accumulated Count Total Value
X
200
X
X
Date/Time as Unix Seconds
X
257
X
X
Indicator Watchdog Counter Value
X
Enables Operator to verify scale is functioning
300
X
X
X
X
Transaction Counter Value
X
310
X
X
Indicator Serial Number
X
313
X
X
Indicator Healthy Status (2-Byte)
X
Output of 2-bytes which indicate any faults. With no
Errors = 0xFFFF
BYTE #1:
Bit 0 = Any Fault
Bit 1 = ADC Error
Bit 2, 3, 4 = N/A
Bit 5 = Overload Condition
Bit 6 = Underload Condition
Bit 7 = N/A
Token
SMA protocol
PLC Protocol
Description of Network Token
Data Type
Notes
Set XVS
Get XVG
Inbound Outbound
INTEGER FLOAT STRING
Содержание T419S
Страница 1: ...AWT35 501788 Issue AC T419S Indicator Service Manual original instructions AMERICAS CONFIDENTIAL ...
Страница 2: ...BTEK_T419S_s_en_501788 book 2019 B TEK All rights reserved ...
Страница 118: ...118 T419S Indicator Service Manual ...
Страница 130: ...130 T419S Indicator Service Manual ...
Страница 134: ...134 T419S Indicator Service Manual Last 28 Temp 28 ...
Страница 135: ......
Страница 136: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088 ...