8
Table 1—Physical Data Con’t -- Unit 677D----A
UNIT SIZE
A48090
A48115
A48130
A60090
A60115
A60130
NOMINAL COOLING CAPACITY (ton)
4
4
4
5
5
5
NOMINAL HEATING CAPACITY (Btu)
90,000
115,000
130,000
90,000
115,000
130,000
SHIPPING WEIGHT (lb)
(kg)
575
261
575
261
575
261
618
280
618
280
618
280
COMPRESSORS
Quantity
Two--Stage Scroll
1
REFRIGERANT: PURON (R--410A)
Quantity (lb)
(kg)
15.5
7.0
15.5
7.0
15.5
7.0
16.0
7.3
16.0
7.3
16.0
7.3
EXPANSION DEVICE--HEATING
AccuRater
Orifice OD (in.) -- Left
0.038
0.038
0.038
0.046
0.046
0.046
Orifice OD (in.) -- Right
0.046
0.046
0.046
0.046
0.046
0.046
EXPANSION DEVICE--COOLING
TXV
Size
4 Ton
4 Ton
4 Ton
5 Ton
5 Ton
5 Ton
OUTDOOR FAN
Nominal Cfm
Diameter (in.)
(mm)
Motor Hp (Rpm)
3300
22
559
1/4 (1100)
3300
22
559
1/4 (1100)
3300
22
559
1/4 (1100)
3300
22
559
1/3 (1110)
3300
22
559
1/3 (1110)
3300
22
559
1/3 (1110)
OUTDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
2...21
19.4
2...21
19.4
2...21
19.4
2...21
23.3
2...21
23.3
2...21
23.3
INDOOR COIL
Rows...Fins/in.
Face Area (sq ft)
3...17
5.7
3...17
5.7
3...17
5.7
4...17
5.7
4...17
5.7
4...17
5.7
INDOOR FAN
Nominal Airflow (Cfm)
Comfort
Variable based on Comfort Roll back (see User Interface instructions for more information).
Efficiency
1400
1400
1400
1750
1750
1750
Max
1600
1600
1600
2000
2000
2000
Furnace (gas ht.) airflow---Low Stage
815
1215
1255
845
1215
1255
Furnace (gas ht.) airflow---High Stage
1385
1885
1875
1300
1910
1920
Size in.
(mm)
11x10
279x254
11x10
279x254
11x10
279x254
11x10
279x254
11x10
279x254
11x10
279x254
Motor HP
3/4
3/4
3/4
1
1
1
FURNACE SECTION*
Burner Orifice No. (Qty...Drill Size)
Natural Gas (Factory Installed)
Propane Gas
3...38
3...53
3...33
3...51
3...31
3...49
3...38
3...53
3...33
3...51
3...31
3...49
HIGH--PRESSURE SWITCH (psig)
Cut--out
Reset (Auto)
670
±
10
470
±
25
HIGH--PRESSURE SWITCH 2 (psig)
(Compressor Solenoid)
Cut--out
Reset (Auto)
565
±
1
5
455
±
15
LOSS--OF--CHARGE /
LOW--PRESSURE SWITCH
(Liquid Line) (psig)
Cut--out
Reset (auto)
23
±
5
55
±
5
RETURN--AIR FILTERS
Throwaway
(in.)†
(mm)
24x36x1
610x914x25
*Based on altitude of 0 to 2000 ft (0---610 m).
{
Recommended filter sizes for field---installed air filter grilles mounted on the wall or ceiling of the conditioned structure. Required filter sizes shown are based on
the larger of the ARI (Air Conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or 450
ft/minute for high---capacity type. Air filter pressure drop for non---standard filters must not exceed 0.08 IN. W.C.
677D
--
--
A
Содержание 677D--A
Страница 5: ...5 A09561 Fig 5 677D A24 30 Unit Dimensions 677D A...
Страница 6: ...6 A09562 Fig 6 677D A36 60 Unit Dimensions 677D A...
Страница 18: ...18 A10217C Fig 17 Connection Wiring Schematic 677D A Single Phase Gas Inputs 040 060 090 kBtu hr 677D A...
Страница 19: ...19 A10217L Fig 16 Cont Ladder Wiring Schematic 677D A Single Phase Gas Inputs 040 060 090 kBtu hr 677D A...
Страница 20: ...20 A10219C Fig 18 Connection Wiring Schematic 677D A Single Phase Gas Inputs 115 130 kBtu hr 677D A...
Страница 21: ...21 A10219L Fig 17 Ladder Wiring Schematic 677D A Single Phase Gas Inputs 115 130 kBtu hr 677D A...