3
Fig. 1 — 580J*08-16 Units Model Number Nomenclature
Model
J - Puron
®
(R-410A) Refrigerant
Unit Type
580 - Gas Heat RTU
Legacy
Series
Packaging and 2-Speed Indoor Fan Motor
A = Standard Packaging, electro-mechanical
controls that require W7212 EconoMi$er
®
IV
B = LTL Packaging, electro-mechanical controls
that require W7212 EconoMi$er IV
C = Standard Packaging, electro-mechanical
controls that require W7220 EconoMi$er X
D = Standard Packaging and 2-Speed Indoor
Fan Motor (VFD) Controller
E = LTL Packaging and 2-Speed Indoor Fan
Motor (VFD) Controller
F = LTL Packaging, electro-mechanical controls
that require W7220 EconoMi$er X
Cooling Tons
08 - 7.5 tons
09 - 8.5 tons
12 - 10 tons
14 - 12.5 tons
16 - 15 tons
Heat Level
Standard/Stainless Steel
125 = 125,000
150 = 150,000
180 = 180,000
224 = 224,000
240 = 240,000
250 = 250,000
350 = 350,000
Indoor Fan Options
1 = Standard Static Option
2 = Medium Static Option
3 = High Static Option (sizes 08-14)
C = High Static Option with High Efficiency Motor (size 16 only)
Refrig. System/Gas Heat Options
D = Two-stage cooling models (08-16)
F = Two-stage cooling models/Stainless Steel gas heat
exchanger
(08-16)
K = Two-stage cooling models/Aluminum gas heat exchanger
with Perfect Humidity
TM
(08-16)
M = Two-stage cooling models/Stainless Steel gas heat
exchanger with Perfect Humidity (08-16)
N = Single Circuit Two-stage cooling (08-12)
P = Single Circut Two-stage cooling/Stainless Steel gas heat
exchanger
(08-12)
Coil Options For Round Tube/Plate Fin Condenser Coil Models Only
(Outdoor - Indoor - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu -Al/Cu — Louvered Hail Guard
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guard
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guard
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guard
R = Cu/Cu - Al/Cu — Louvered Hail Guard
S = Cu/Cu - Cu/Cu — Louvered Hail Guard
Coil Options For All Aluminum - Novation
®
Condenser Coil Models Only
(Outdoor - Indoor - Hail Guard)
G = Al/Al - Al/Cu
H = Al/Al - Cu/Cu
J = Al/Al - E-coat Al/Cu
K = E-coat Al/Al - Al/Cu
L = E-coat Al/Al - E-coat Al/Cu
T = Al/Al - Al/Cu — Louvered Hail Guard
U = Al/Al - Cu/Cu — Louvered Hail Guard
V = Al/Al - E-coat Al/Cu — Louvered Hail Guard
W = E-coat Al/Al - Al/Cu — Louvered Hail Guard
X = E-coat Al/Al - E-coat Al/Cu — Louvered Hail Guard
Voltage
E = 460-3-60
P = 208/230-3-60
T = 575-3-60
Example:
Position:
5
8
0
J
E
0
8
D
1
2
5
A
1
B
0
A
A
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Factory Installed Options
0A =
None
NOTE:
See the 580J 6 to 15 ton Price Pages for a
complete list of factory installed options.
Outdoor Air Options
A = None
B = Temperature Economizer, Barometric Relief,
Standard Leak (W7212 or W7220)
E = Temperature Economizer, Barometric Relief,
Standard Leak with CO
2
, (W7212 or W7220)
H = Enthalpy Economizer, Barometric Relief,
Standard Leak, (W7212 or W7220)
L = Enthalpy Economizer,Barometric Relief,
Standard Leak with CO
2
, (W7212 or W7220)
Q = Motorized 2 Position Damper
U = Temperature Economizer, Barometric Relief,
Ultra Low Leak, (W7220)
W = Enthalpy Economizer, Barometric Relief,
Ultra Low Leak, (W7220)
Содержание 580J*16D Series
Страница 4: ...4 Fig 2 Unit Dimensional Drawing Sizes 08 09 and 12 ...
Страница 5: ...5 Fig 2 Unit Dimensional Drawing Sizes 08 09 and 12 cont ...
Страница 6: ...6 Fig 3 Unit Dimensional Drawing Size 14 ...
Страница 7: ...7 Fig 3 Unit Dimensional Drawing Size 14 cont ...
Страница 8: ...8 Fig 4 Unit Dimensional Drawing Size 16 ...
Страница 9: ...9 Fig 4 Unit Dimensional Drawing Size 16 cont ...
Страница 15: ...15 Fig 9 580J 16 Roof Curb Details ...
Страница 32: ...32 Fig 58 580J 08 14 Typical Perfect Humidity Dehumidification System Humidistat Wiring ...
Страница 33: ...33 Fig 59 580J 16 Typical Perfect Humidity Dehumidification System Humidistat Wiring ...
Страница 48: ...48 Fig 67 580J 08 12N P Typical RTU Open System Control Wiring Diagram ...
Страница 49: ...49 Fig 68 580J 08 14 Typical RTU Open System Control Wiring Diagram ...
Страница 50: ...50 Fig 69 580J 16 Typical RTU Open System Control Wiring Diagram ...
Страница 51: ...51 Fig 70 580J 8 14 Typical RTU Open System Control Wiring Diagram with Perfect Humidity System ...
Страница 52: ...52 Fig 71 580J 16 Typical RTU Open System Control Wiring Diagram with Perfect Humidity System ...