17
Technical data
and start-up
NLG5 charger
5
Use and Limits of the Product
5.1
Proper Use
The BRUSA NLG5 charger has been designed for the following uses. In the case of planned operations in other
areas, please contact the company BRUSA Elektronik AG beforehand at the manufacturer address as given in
Universal charger for charging of various batteries e.g.
NiCd batteries
Pb batteries
Li-Ion batteries
The user must ensure at all times during a charging process that the specific operational limits of the
connected battery are never exceeded.
The charger may only be operated within the limits given in chapter
INFORMATION
This equipment is a custom built evaluation unit destined for professionals to be used solely at
research and development facilities for such purposes.
5.2
Improper Use / Limits of the Product
The carrying out of applications which do not conform to the conditions and requirements stated in the technical
documents and datasheets of the manufacturer is viewed as improper use.
The following limit values are set for the operation of the NLG5 charger . Operation outside these defined limits can
lead to life-threatening situations and is therefore forbidden!
Max. AC input voltage
265 V
AC
DC output voltage range
0 - 520 V
DC
Battery voltage range
200 – 520 V
DC
Min. ambient temperature
- 25°C
Max. ambient temperature
+ 70°C
Min. coolant temperature
- 25°C
Max. coolant temperature
+ 70°C
Maximum pressure cooling water system
1.0 bar
INFORMATION
The functioning of the charger can only be guaranteed if the given voltage range is observed!
Batteries with differing loads will lead to malfunctioning of the charger!