Technical data
and start-up
NLG5 charger
32
6.8.4.7
Pin 9 CNL, Pin 10 CNH
Internal wiring
2x47p
Pin 9
CNL
Pin 10
CNH
20nF
2x
±33V
Isolated CAN-
Transceiver
2x51uH
The CAN interface has the following features / possibilities:
CAN 2.0 B, 500 kHz (default) - parameters can be set (125 / 250 / 500 / 1000 kBit/s).
Both pins are electrically isolated from the ground
GND
(avoiding faults through potential shifts).
Without termination resistor (no CAN termination).
6 messages in total can be transmitted via the CAN interface. You can find details on this in the
Software
manual.