59
Technical information
and start-up
BSC624-12V-B
9.1
Producing the cable glands for the HV power connector
The HV wiring is to be implemented in accordance with the following instructions. Here, it is important to ensure
that no strands are damaged. For this reason, check the correct mounting of the screw connection of each
complete cable as well as the tight fit of the crimp contact sockets (pull test).
For the HV connections we recommend:
Screened, isolated automotive cable (e.g. by Huber & Suhner).
Harting high voltage connector set HAN-Modular Compact, see chapter
When assembling the cable lugs, using the appropriate crimping tool is absolutely necessary!
PROCEDURE STEP
ILLUSTRATION / OTHER INFORMATION
1.
Strip the HV cable (1) to a length of 40 mm.
Ensure that the braid underneath is not
damaged!
2.
Shorten the braid (1) to 15 mm.