51
Technical information
and start-up
BSC624-12V-B
8
Connections
8.1
Control connector
INSTRUCTION
The control connector has been designed for a maximum number of 10 cycles of connector
operation! The manufacturer guarantees the full functioning (conductance, tightness) up to this
quantity.
For a professional mounting of the AMPSEAL contacts SN/LP, we recommend the usage of the
following crimping tool:
Tyco 58440-1
INFORMATION
Control connector included in the scope of delivery has to be assembled in accordance with the
respective requirements (EMC, environmental impacts etc.). Here, only the actually used pins are to
be wired (mandatory* and/or urgently recommended**).
Pin 3
EN
is to be connected to pin 2
AUX
via a switch (e.g.: in the vehicle via the ignition key with the
wiring system Plus).
1.
GND *
Signal ground
(Minus wiring system, terminal 31)
2.
AUX *
+12 V
(Plus wiring system, terminal 30)
3.
EN *
Enable (power ON, terminal 15)
4.
DO0
5.
DO1
6.
DO2
7.
DO3
8.
PG1
9.
CNL *
CAN low
10.
CNH *
CAN high
11.
TXD **
RS232 Transmit (9 pole D-Sub: pin 2)
12.
RXD **
RS232 Receive (9 pole D-Sub: pin 3)
13.
PRO **
Enable firmware download
14.
PG2
15.
PG3 **
RS232 ground (9 pole D-Sub: 5 pin)
16.
DI0
17.
DI1
18.
DI2
19.
IL1 **
HV interlock loop input
20.
IL2 **
HV interlock loop output
21.
AI1
22.
AI2
23.