Technical information
and start-up
BSC624-12V-B
68
10.3
Operation of the device
INFORMATION
Optionally, the CAN user interface (CVI) may also be implemented by BRUSA if the device is not
integrated into an existing CAN communication network. The following image shows an example of
the user interface. Here, the start-up is implemented as described.
The CVI software serves as user interface for internal laboratory applications for
BRUSA Elektronik AG. The CVI is provided to customers as example for a custom user interface for
first tests with no guarantee.
Connect pin 3
EN
with pin 2
AUX
(e.g. actuate ignition key, close switch etc.).
Start the CAN user interface and press the
Go
button in order to enable the communication with the device.
Press the
Run
button in order to activate the power stage. The communication with the device is ensured
when the displays
Tx
and
Rx
are flashing.
To allow for the main controller to fulfil its function, it is to be guaranteed that no limiting controller is
meshed.
The device can be switched off in every operating mode by another actuation of the Run button and a
deactivation of pin 3 EN. In the case of an emergency, an abrupt disconnection of the high voltage by opening
the contactors is also admissible.