VIBROTEST 60
Field Balancing
_________________________________________________________________________________
© VTEST60E July 2013 V4.46ff
C102 853.002
Page 125 of 168
VIBROTEST 60 dialogue
VIBROTEST 60 steps
Activity at Rotor
Store the measurement with
»NO«.
6.
Store Test run A
To calculate the correction weight the
VIBROTEST 60 must be informed
whether the test weight A will be
removed from the rotor.
•
»YES« - the test weight A will be
removed.
•
»NO« - the test weight A will
remain and is taken into
consideration in the calcu-lation of
the correction weight.
Stop the rotor.
With »YES«: Remove
the test weight from the
rotor.
Test Run B
A
B
1
2
Select Test run B with
»SELECT«.
1.
Select test run B in the
main menu
Open the test weight B entry
menu with »EDIT«.
2.
Change test weight B
The VIBROTEST 60 recommends a
magnitude for the test weight for
plane B. The magnitude of this test
weight can be changed.
•
Enter the magnitude and
location of test weight B.
•
Confirm the entry with
»OK«.
3.
Enter test weight B
The VIBROTEST 60 stores the
details of test weight B.
Attach the test weight
at plane B on the rotor
(e.g. 80 g at location
1).
Start the measurement with
»START«.
4.
Start Test run B
The measurement is executed by
VIBROTEST 60 with »START«.
Test weight B (TMB) is displayed in
the measurement menu.
Bring the rotor to
operational speed.