4-32
3.Remove the sensor frame screw from the sensor frame. Attach the ground wire and
fasten it with the sensor frame screw.
Ground wire
Sensor frame
Sensor frame screw
Fig. 4.16-3 Installing the Chassis Unit (3)
4.16.2 Installing the PE Sensor Unit
1.Engage the tip of the PE sensor unit with the paper sensor crank. Attach the PE
sensor unit to the paper feed roller, such that the sensor is located vertically above
the paper sensor crank. Take care not to damage the tip of the PE sensor unit
during installation.
2.Open the bottom cover bearing supports outward and mount the PE sensor unit in the
bearing supports.
Fig. 4.16-4 Installing the PE Sensor Unit
PE sensor unit
Paper feed roller
Paper sensor crank
Bearing supports
Paper sensor crank
PE sensor unit