3-9
3.3.8 Removing the Dial Switch Holder Assy B
1.Disconnect the leaf switch R assy (red CN2) and leaf switch L assy (white CN3)
harness connectors from the switch PCB.
2.Remove the dial lock arm and the dial lock arm spring that is hooked on the body
cover.
3.Remove the switch harness assy from switch PCB.
4.Remove the two dial holder screws. Remove the Dial Switch Holder Assy B.
Dial holder screws
Leaf switch L
assy
Leaf switch R
assy
Dial lock arm spring
Dial lock arm
Dial switch
holder
assy B
Fig. 3.3-13 Removing the Dial Switch Holder Assy B