6-18
6.3.2 Adjusting the Left Y-cutting Position
Loosen the screw and move the photosensor (PS) PCB holder left or right. This moves
the detection position of the sensor attached to the photosensor (PS) PCB holder and
adjusts the cutting position for the left edge of the sheet.
In the diagram below, move the photosensor (PS) PCB holder to the right to increase
the border of the laminated document.
Screw
Photosensor (PS) PCB holder
Y-cutter arm L
Fig. 6.3-2 Adjusting the Left Y-cutting Position
Содержание LX-200
Страница 1: ...SERVICE MANUAL MODEL LX 200 LX 900 LX 910D REVISED EDITION May 2000 ...
Страница 4: ...Chapter 1 SPECIFICATIONS ...
Страница 8: ...Chapter 2 MECHANISMS ...
Страница 18: ...Chapter 3 DISASSEMBLY PROCEDURES ...
Страница 60: ...Chapter 4 REASSEMBLY PROCEDURES ...
Страница 107: ...Chapter 5 ELECTRONIC CONTROLLERS ...
Страница 128: ...Chapter 6 MAINTENANCE ...
Страница 137: ...6 8 Y Diversion Lever E two positions Ring Y cutter guide shaft Y diversion lever assy Fig 6 1 14 Y Diversion Lever ...
Страница 151: ...Chapter 7 TROUBLESHOOTING ...
Страница 176: ...APP 1 Appendix Main PCB Circuit Diagram ...
Страница 177: ...May 2000 86S004BE3 Printed in Japan ...