7-9
Problem
Check Item
Cause
Remedy
Repair
See
Section
d. Abnormal Y-
carriage power
ON processing
Sensor lever cuts
photosensor at start position?
Deformed sensor frame
unit?
Replace the sensor
frame unit.
3.3.3
Photosensor cut off when not
at start position?
Sensor lever incorrectly
installed.
3.3.4
3.3.5
Defective sensor lever.
Replace the sensor
lever.
3.8
Error during Y-carriage
position detection?
See
9
Document width cannot be detected correctly.
e. Abnormal Y-
cutter power
ON processing
Error during Y-cutter position
detection?
See
11
No cutting in Y direction.
Содержание LX-200